Related Experiment Video
Updated: Jan 22, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Repeatability of tumor blood flow quantification with 82Rubidium PET/CT in prostate cancer - a test-retest study
Mads Ryø Jochumsen1,2, Kirsten Bouchelouche3,4, Katrine Bødkergaard Nielsen5
1Department of Nuclear Medicine and PET-Centre, Aarhus University Hospital, Palle Juul-Jensens Boulevard 165, 8200, Aarhus N, Denmark. madsjoch@rm.dk.
Background:
Non-invasive tumor blood flow (TBF) quantification is a candidate approach for risk stratification and monitoring of prostate cancer patients. Validation data have recently been published on prostate TBF measurement with the widely used positron emission tomography (PET) flow tracer 82Rubidium (82Rb). However, no test-retest data is available for TBF measurement with 82Rb PET in prostate cancer. Such information is important to determine the potential clinical usefulness of the technique. The aim of the present study was to determine the test-retest repeatability of TBF measurement with both dynamic and static 82Rb PET.
Methods:
We recruited 10 low-to-high-risk prostate cancer patients scheduled for clinical prostate-specific membrane antigen (PSMA) PET/computed tomography (CT) or magnetic resonance imaging. Pelvic and cardiac static and dynamic 82Rb PET/CT were performed at baseline and repeated on a different day within 1 week. In total, 11 primary lesions were analyzed.
Results:
For K1, standardized uptake values (SUV)max, SUVmean, and SUVpeak, prostate cancer 82Rb PET TBF has a repeatability of 32%, 51%, 53%, and 58% and an intraclass correlation of 0.98, 0.89, 0.88, and 0.88, respectively.
Conclusion:
Dynamic 82Rb PET/CT with kinetic modeling measures TBF in prostate cancer with high repeatability, which allows identification of blood flow changes of 32%. Static late-uptake 82Rb PET/CT is inferior, and only intra-individual blood flow changes above 51% can hence be recognized.
Related Concept Videos
Blood Flow
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Cancer Stem Cells and Tumor Maintenance
Cancer stem cells are thought to originate from tissue-specific normal stem cells or progenitor cells. The normal stem cells usually reside in...

