Related Experiment Video
Updated: Jan 22, 2026

Myocardial Infarction by Percutaneous Embolization Coil Deployment in a Swine Model
Published on: November 4, 2021
A coronary cameral fistula treated with coil embolization
Ethan D Hinds1, Manuel J Marin2, Joggy George2
1School of Medicine, University of Texas Medical Branch, Galveston, USA.
Insights
A rare coronary cameral fistula developed in a heart transplant patient. Coil embolization successfully treated the fistula, resolving symptoms and normalizing heart function.
Area of Science:
- Cardiology
- Cardiovascular Surgery
Background:
- Recurrent heart failure symptoms in a patient with a history of two orthotopic heart transplantations.
- Exclusion of cardiac allograft rejection via biopsy.
Observation:
- Left heart catheterization identified a coronary cameral fistula.
- Initial conservative management with diuretics provided temporary relief.
- Readmission due to worsening chest pain and dyspnea, with elevated left ventricular end-diastolic pressure and increased fistula flow.
Findings:
- Successful coil embolization of the coronary cameral fistula without complications.
- Resolution of patient's symptoms and normalization of left ventricular end-diastolic pressure post-procedure.
Implications:
- Coronary cameral fistulas may arise from cardiac trauma during de-airing procedures in heart transplantation.
- Potential for prevention through improved de-airing techniques in cardiac surgery.
Abstract:
A 56-year-old man who had twice previously undergone orthotopic heart transplantation was admitted with dyspnea and heart failure symptoms. A biopsy excluded rejection. Left heart catheterization revealed a coronary cameral fistula. After the patient was given mild diuretics, his condition improved. No significant fistula flow was detected, and he was discharged. Several months later, the patient was readmitted with worsening chest pain and dyspnea. Left ventricular end-diastolic pressure and flow through the fistula were increased. To correct the coronary cameral fistula, we performed a coil embolization without complications. Several months later at follow-up, the patient's symptoms had resolved, and his left ventricular end-diastolic pressure had normalized. We conclude that coronary fistulas may be caused by trauma to the heart during the de-airing process, which may be prevented in the future with the development of safer and more effective de-airing techniques.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
09:30Treating Clinical Depression with Repetitive Deep Transcranial Magnetic Stimulation Using the Brainsway H1-coil
Published on: October 4, 2016
Related Concept Videos
Pulmonary Embolism I: Introduction
Coronary Circulation
Coronary circulation begins at the base of the aorta, where two main arteries arise—the left and right coronary arteries. These arteries encircle the heart in the coronary sulcus and supply the...
Pulmonary Embolism III: Nursing Management
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Coronary Artery Disease I: Introduction
Coronary Artery Disease II: Pathophysiology