Self-powered nano-porous aerogel x-ray sensor employing fast electron current
Davide Brivio1, Steffen Albert1,2,3, Erica Freund2
1Department of Radiation Oncology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, 02115, USA.
Purpose:
We developed a new class of aerogel-based thin-film self-powered radiation sensors employing high-energy electron current (HEC) in periodic multilayer (high-Z | polyimide aerogel (PA) | low-Z) electrode microstructures.
Materials:
Low-Z (Al) and high-Z (Ta) electrodes were deposited on 50 μm-thick PA films to obtain sensors with Al-PA-Ta-PA-Al structures. Sensors were tested with x rays in the 40-120 kVp range and with 2.5 MV, 6 MV, and 6 MV-FFF linac beams (TrueBeam, Varian). Performance of PA-HEC sensors was compared to commercial A12 Farmer ionization chamber as well as to radiation transport simulations using CEPXS/ONEDANT with nanometer-to-micrometer spatial resolution. The computations included periodic and single-element structures N x (Al-PA-Ta-PA-Al) with variable layer thicknesses.
Results:
Signal from PA-HEC sensors was proportional to the simulated net leakage electron current (averaged over the PA thickness). Experimental response was linear with dose and independent of dose rate. Detector responses to different x-ray sources show higher signals for kVp photon energies, as expected, though a strong signal was obtained for MV energies as well. The signal scaled with total effective area inside the multielemental structures; for example, the yield of a multielement sensor made with 20 Ta layers compared to a single-element structure with 1 Ta layer of the same total thickness of Ta was 10 times greater for 6 MV beam and 23 times greater for 120 kVp. Beam attenuation per element in the detector was 0.5%, 1%, 3%, and 46%, respectively for 6 MV, 6 MV FFF, 2.5 MV, and 120 kVp.
Conclusion:
We demonstrated the feasibility of aerogel-based multilayer HEC radiation detector and its application for flux/dose monitoring of kVp and radiotherapy MV beams with small beam attenuation.
Related Concept Videos
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
Power
Electron Carriers
Over the many stages of cellular respiration, glucose breaks down into carbon dioxide and water. Electron carriers pick up electrons lost by glucose in these reactions, temporarily storing and releasing them into the electron...
Power System Distribution
The transmission system is designed...
Power and Energy
Power, defined as the time rate of expending or absorbing energy, is quantified in units called watts (W). The relation between power and energy is mathematically given as