Related Experiment Video
Updated: Jan 22, 2026

Subdural Soft Electrocorticography ECoG Array Implantation and Long-Term Cortical Recording in Minipigs
Published on: March 31, 2023
A 360° electronic device for recording high-resolution intraoperative electrocorticography of the brain during awake
Karim ReFaey1, Kaisorn L Chaichana1, Anteneh M Feyissa2
1Departments of1Neurosurgery and.
Objective:
Epilepsy is common among patients with supratentorial brain tumors; approximately 40%-70% of patients with glioma develop brain tumor-related epilepsy (BTRE). Intraoperative localization of the epileptogenic zone during surgical tumor resection (real-time data) may improve intervention techniques in patients with lesional epilepsy, including BTRE. Accurate localization of the epileptogenic signals requires electrodes with high-density spatial organization that must be placed on the cortical surface during surgery. The authors investigated a 360° high-density ring-shaped cortical electrode assembly device, called the "circular grid," that allows for simultaneous tumor resection and real-time electrophysiology data recording from the brain surface.
Methods:
The authors collected data from 99 patients who underwent awake craniotomy from January 2008 to December 2018 (29 patients with the circular grid and 70 patients with strip electrodes), of whom 50 patients were matched-pair analyzed (25 patients with the circular grid and 25 patients with strip electrodes). Multiple variables were then retrospectively assessed to determine if utilization of this device provides more accurate real-time data and improves patient outcomes.
Results:
Matched-pair analysis showed higher extent of resection (p = 0.03) and a shorter transient motor recovery period during the hospitalization course (by approximately 6.6 days, p ≤ 0.05) in the circular grid patients. Postoperative versus preoperative Karnofsky Performance Scale (KPS) score difference/drop was greater for the strip electrode patients (p = 0.007). No significant difference in postoperative seizures between the 2 groups was present (p = 0.80).
Conclusions:
The circular grid is a safe, feasible tool that grants direct access to the cortical surgical surface for tissue resection while simultaneously monitoring electrical activity. Application of the circular grid to different brain pathologies may improve intraoperative epileptogenic detection accuracy and functional outcomes, while decreasing postoperative complications.
Related Concept Videos
Electron Carriers
Over the many stages of cellular respiration, glucose breaks down into carbon dioxide and water. Electron carriers pick up electrons lost by glucose in these reactions, temporarily storing and releasing them into the electron...
Electron Affinity
Electron Behavior
Electrons are negatively charged subatomic particles that are attracted to an orbit around the positively-charged nucleus of an atom. They reside in locations that are associated with energy levels called shells and are further organized into sub-shells and orbitals within each shell.
Electrons Orbit the Nucleus
Electrons are found in specific locations outside of the nucleus. The shell in which an electron resides indicates the general energy level of the electron: those closer to the...
Electron Transport Chains
The ETC is comprised of...
Electron Orbital Model
The first shell is closest to the nucleus, and it has only one subshell with a single spherical orbital called the...
Data Reporting and Recording