Volume and vascularity: Using ultrasound to unlock the secrets of the first trimester placenta

S Mathewlynn1, S L Collins2

  • 1Department of Obstetrics and Gynaecology, Milton Keynes University Hospital, Milton Keynes, UK.

Placenta
|July 8, 2019
PubMed

Fetal growth restriction (FGR) is a major cause of perinatal morbidity and mortality. Identifying which pregnancies are at risk of FGR facilitates enhanced surveillance and early delivery before fetal demise can ensue. However, existing risk stratification strategies yield an unacceptably low detection rate. A robust and reliable first trimester screening test for FGR would not only enable high-risk women to be appropriately monitored but would facilitate future trials for possible interventions to enhance fetal growth. Both the volume and vascularity of the first trimester placenta has been demonstrated to be linked to adverse pregnancy outcomes including FGR and pre-eclampsia. The investigation of novel ultrasound markers for FGR are discussed along with the development of methods for fully automatic placental volume estimation which has the potential for use as part of a multi-variable population-based screening test.

Related Concept Videos

Seedless Vascular Plants03:24

Seedless Vascular Plants

Seedless Vascular Plants Were the First Tall Plants on Earth
66.7K
Ultrasound II: Endoscopic Ultrasound and FibroScan01:25

Ultrasound II: Endoscopic Ultrasound and FibroScan

Endoscopic Ultrasound (EUS) and FibroScan are valuable diagnostic tools in gastroenterology and hepatology, each with specific applications and techniques.
Endoscopic Ultrasound (EUS):
608
Constant Volume Calorimetry02:41

Constant Volume Calorimetry

Calorimeters are useful to determine the heat released or absorbed by a chemical reaction. Coffee cup calorimeters are designed to operate at constant (atmospheric) pressure and are convenient to measure heat flow (or enthalpy change) accompanying processes that occur in solution at constant pressure. A different type of calorimeter that operates at constant volume, colloquially known as a bomb calorimeter, is used to measure the energy produced by reactions that yield large amounts of heat and...
30.6K
Volume of Distribution01:20

Volume of Distribution

The apparent volume of distribution (Vd) is a crucial pharmacokinetic parameter representing the hypothetical body fluid volume into which a drug disperses. It is calculated based on the total amount of drug in the body (estimated from the administered dose and bioavailability) divided by the plasma drug concentration. The total amount of drug in the body does not directly refer to the dose given but is derived by accounting for absorption, distribution, metabolism, and excretion processes.
1.2K
Work Done During Volume Change01:17

Work Done During Volume Change

In mechanics, work is done on an object when the force acting on it displaces the object. In thermodynamics, work done on a system can be estimated when the system's volume changes during any thermodynamic process.
Consider a gas confined to a cylinder fitted with a movable piston at one end. If the gas expands from volume V1 to volume V2, it exerts a force on the piston, such that the piston moves by a distance dr.
The work done by the gas on the piston can be expressed as
5.1K
Respiratory Volumes01:15

Respiratory Volumes

Respiratory volumes are crucial metrics, meticulously measured to quantify the air exchanged in and out of the lungs during various phases of the breathing cycle. These precise measurements are vital for assessing lung function, diagnosing respiratory conditions, and monitoring overall respiratory health. Each parameter provides specific insights into the mechanics of breathing and the functional capacity of the lungs.
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
2.9K