Corrigendum: Melatonin Protects MCAO-Induced Neuronal Loss via NR2A Mediated Prosurvival Pathways

Fawad Ali Shah1,2, Gongping Liu3,4, Lina T Al Kury5

  • 1State Key Laboratory of Oncogenomics, School of Chemical Biology and Biotechnology, Peking University Shenzhen Graduate School, Shenzhen, China.

Insights

This study details corrections to a previously published article, ensuring the accuracy of its scientific content and DOI reference for future research.

Area of Science:

  • Pharmacology and Toxicology
  • Scientific Publishing Ethics

Background:

  • Ensuring the integrity of scientific literature is crucial.
  • Accurate referencing facilitates proper citation and reproducibility.

Purpose of the Study:

  • To correct an erroneous article DOI.
  • To maintain the accuracy of the scientific record.

Main Methods:

  • Article DOI verification.
  • Correction notice publication.

Main Results:

  • The article DOI has been corrected to 10.3389/fphar.2019.00297.
  • The scientific record is now accurate.

Conclusions:

  • Accurate DOIs are essential for scientific communication.
  • This correction ensures the article is discoverable and correctly attributed.

Related Concept Videos

C4 Pathway and CAM01:27

C4 Pathway and CAM

Most plants use the C3 pathway for carbon fixation. However, some plants, such as sugar cane, corn, and cacti that grow in hot conditions, use alternative pathways to fix carbon and conserve energy loss due to photorespiration. Photorespiration is the process that occurs when the oxygen concentration is high. Under such conditions, the rubisco enzyme in the Calvin cycle binds O2 instead of CO2, which halts photosynthesis and consumes energy.
C4 Pathway
The C4 pathway is used by plants such as...
48.9K
Line Loss01:10

Line Loss

The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
517
Reducing Line Loss01:18

Reducing Line Loss

In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
370
Zones of Protection01:16

Zones of Protection

In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
770
Protection of Alcohols02:31

Protection of Alcohols

This lesson delves into the concept of protection and deprotection of a functional group fundamental to synthetic organic chemistry. These phenomena are explained in the context of aliphatic and aromatic alcohols.
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
8.0K
Major Losses in Pipes01:28

Major Losses in Pipes

When a fluid flows through a pipe, it experiences energy losses due to frictional resistance along the pipe walls, known as major losses. These energy losses result in a pressure drop, which varies based on the flow conditions — whether laminar or turbulent — and the specific physical properties of the fluid and pipe.
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
1.9K