Radial extracorporeal shock wave therapy in flexor tendon pathology of the hand: A feasibility study
Christoph Lutter1,2, Volker Schöffl2,3, Thilo Hotfiel4,5
1Department of Orthopedics, University Medical Center, Rostock, Germany.
Background:
Radial extracorporeal shock wave therapy (rESWT) is an effective and safe non-invasive therapeutic option for various musculoskeletal pathologies. However, data on possible application of radial extracorporeal shock waves (rESWs) on soft tissue components of fingers is still scarce.
Objective:
We now aimed to analyze the feasibility of applying rESWs to human fingers ex vivo.
Methods:
Fresh frozen human cadaveric fingers were exposed to rESWs of varying energy density. The penetration of the rESWs into the soft tissue was determined using pressure sensitive Fuji films that were placed underneath the flexor tendons and other soft tissue components at the proximal phalanx. Then, rESWs were applied and activation of the Fuji film was recorded. Software based image analysis was performed on all films treated with rESWT under ultrasound gel.
Results:
Penetration of the rESWs through the soft tissue was detected in all settings. Increasing energy density of the rESWs resulted in increasing film activation. Image analysis of films used under ultrasound showed a significant difference among the groups.
Conclusion:
The results of this study demonstrate that rESWs can penetrate soft tissues including the flexor tendons of human cadaveric fingers. rESWT should be considered as a valuable potential therapeutic option of different finger pathologies. Further studies focusing on the clinical application of rESWT for finger pathologies are required.
Related Concept Videos
Shock Waves
When the source's speed approaches the speed of sound, constructive interference between successive wavefronts emitted by the source occurs immediately behind it. Initially, scientists believed that this constructive interference would result in such high...
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
The Wave Nature of Light
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Hand hygiene
Hand washing...