Related Experiment Video
Updated: Jan 22, 2026

Author Spotlight: A Simple and Cost-Effective Method for Leukocyte Analysis in Semen
Published on: January 19, 2024
Analysis of Detection of Mixed Semen Stains with Different Immunological Test Methods and Case Applications
M A Dong1,2, M L Li1, M S Cai1
1School of Basic Medical Sciences, Guangzhou Medical University, Guangzhou 510000, China.
Abstract:
Objective To perform the separation and confirmation of mixed semen stains with immunological test method, and find a more effective method for the detection of mixed semen stains. Methods The semens of three volunteers were mixed. The mixed semen stains were processed and tested with prostate-specific antigen (PSA) colloidal gold immunoassay strip method, immunomagnetic beads method and laser capture microdissection, respectively. Statistics of the results of STR were gathered and compared with those of a single semen stain. Results After PSA colloidal gold immunoassay strip method testing, the samples showed a purplish red line in the test area and the control area. The results obtained with the immunomagnetic beads method showed a more complete and effective short tandem repeat (STR) sequence. The mixed semen stains were processed with laser capture microdissection and low volume amplified. The results were summarized and superimposed to obtain a complete single typing, which matched the single semen stain typing, with a typing success rate of 84.00%. Single suspect Y-STR typing was obtained with the application of the method above in actual cases, which provided evidence basis for rapid solving of the case. Conclusion The combination of PSA colloidal gold immunoassay strip method, immunomagnetic beads method and laser capture microdissection can be used to separate and confirm the mixed semen stains.
Related Concept Videos
Sperm Structure and Semen Composition
Immunological Memory
What is Immunological Memory?
Immunological memory is an integral function of the immune system that allows it to recognize and react more rapidly and effectively to pathogens previously encountered. This feature...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Mixing Concrete
Mixing Time
Ready Mixed Concrete

