Related Experiment Video
Updated: Jan 22, 2026

Video Movement Analysis Using Smartphones ViMAS: A Pilot Study
Published on: March 14, 2017
Concurrent validity and reliability of cephalometric analysis using smartphone apps and computer software
Objectives:
To assess the diagnostic accuracy of two smartphone cephalometric analysis apps compared with Viewbox software.
Materials And Methods:
Pretreatment digital lateral cephalograms of 50 consecutive orthodontic patients (20 males, 30 females; mean age, 19.1 years; SD, 11.7) were traced twice using two apps (ie, CephNinja and OneCeph), with Viewbox used as the gold standard computer software program. Seven angular and two linear measurements, originally derived from Steiner cephalometric analysis, were performed.
Results:
Regarding validity, intraclass correlation coefficients (ICCs) ranged from .903-.983 and .786-.978 for OneCeph vs Viewbox and CephNinja vs Viewbox, respectively. The ICC values for intratool reliability ranged from .647-.993. None of the CephNinja measurements was below the recommended cutoff values of ICCs for reliability.
Conclusions:
OneCeph has a high validity compared with Viewbox, while CephNinja is the best alternative to Viewbox regarding reliability. Smartphone apps may have a great potential in supplementing traditional cephalometric analysis.
Related Concept Videos
Reliability and Validity
Statistical Software for Data Analysis and Clinical Trials
Distribution Reliability and Automation
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Data Validation
Key parameters for method validation include:
Formulating and Validating Nursing Diagnosis II
Risk nursing diagnoses represent clinical judgments of an individual, family, or community more vulnerable to developing the health problem than others...