Output Characteristics and Circuit Modeling of Wiegand Sensor
Xiaoya Sun1, Tsutomu Yamada1, Yasushi Takemura2
1Electrical and Computer Engineering, Yokohama National University, Yokohama 240-8501, Japan.
Abstract:
A fast magnetization reversal in a twisted FeCoV wire induces a pulse voltage in a pick-up coil wound around a wire. The Wiegand sensor is composed of this magnetic wire and the pick-up coil. As the output pulse voltage does not depend on a changing ratio of the applied magnetic field to switch the magnetization of the wire, the Wiegand sensor is used for to perform rotation and other detections. Recently, the Wiegand sensor has attracted significant attention as a power supply for battery-less operation of electric devices and for energy harvesting. In this study, we propose a concept of obtaining an intrinsic pulse voltage from the Wiegand sensor as its power source, and demonstrate its effectiveness in circuit simulation. The equivalent circuit for the Wiegand sensor is expressed by the intrinsic pulse voltage, internal resistance, and inductance of the pick-up coil. This voltage as a power source and circuit parameters are determined by MATLAB/Simulink simulation. The output voltage calculated using the equivalent circuit of the Wiegand sensor agrees with the experimentally measured results.
More Related Videos
08:25Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver
Published on: August 27, 2021
13:56Modeling Biological Membranes with Circuit Boards and Measuring Electrical Signals in Axons: Student Laboratory Exercises
Published on: January 18, 2011
Related Concept Videos
Characteristics of Series Resonant Circuit
Modeling of Diode Forward Characteristics
Modeling of Diode Reverse Characteristics
When a reverse voltage applied to a Zener diode exceeds its breakdown voltage, the diode enters the breakdown region. At this point, the...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Characteristics of Life
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...