Detection of intracranial hematomas in the emergency department using near infrared spectroscopy
Vassilios Kontojannis1, Isabel Hostettler2, Robert James Brogan3
1a Neurosurgery , Imperial College London Centre for Neuroscience , London , UK.
Abstract:
Hypothesis: Traumatic brain injury (TBI) is one of the most important causes of morbidity and mortality in our society. The development of near infrared technology for the detection of intracranial hematomas may assist earlier diagnosis of TBI. This in turn may enable earlier targeted treatments minimizing the harm and subsequent social and economic effects of TBI. Methods: A handheld, noninvasive Near Infrared Spectroscopy device, Infrascanner 2000, (Infrascan Inc., Philadelphia, PA, USA) was used in a major trauma center to screen for traumatic intracranial hematomas. The Infrascanner was used successfully in 205 patients on their arrival in the emergency department prior to CT head. Results: In the whole cohort, sensitivity was 75%, specificity was 50.43%, with negative predictive value 72.84%, and positive predictive value 53.23%. In 45 patients, where the volume of blood was >3.5mL, the sensitivity was 89.36%, specificity 48.73% with negative predictive value 93.9% and positive predictive value 34.15%. Conclusions: The Infrascanner has a relatively high specificity and negative predictive value; therefore, it could in association with the Neurological examination, help in the triage of the trauma patient with potential brain injury. Further investigation is necessary to determine the use of Infrascanner 2000 as a diagnostic method in TBI.
More Related Videos
04:05Author Spotlight: Unveiling Prognostic Indicators in Heart Failure - The Role of Phase Angle and Bioelectrical Impedance Analysis
Published on: June 30, 2023
07:52Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Related Concept Videos
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Emerging Adulthood
Introduction Cardiac Emergencies
Applications of GIS: Disaster Management and Emergency Response
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...