Stand-alone surgical ablation for atrial fibrillation: a novel bilateral double-port approach
Huiming Guo1, Hongkun Qing1, Yuyuan Zhang1
1Department of Cardiac Surgery, Atrial Fibrillation Center, Guangdong Cardiovascular Institute, Guangdong Provincial Key Laboratory of South China Structural Heart Disease, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou 510080, China.
Background:
To explore an effective, reproducible and less invasive surgical approach for lone atrial fibrillation (AF).
Methods:
A modified "mini-maze" including pulmonary vein isolation (PVI), box-lesion and left atrial appendage (LAA) resection was applied for AF patients in our center from January 2016 to June 2017. A 2.5 cm thoracotomy extended with tissue retractor was made as working port in the fourth intercostal space on each anterior side of the chest. The thoracoscope was inserted in another port lateral to main port for observing. During PVI, the tip of the clamp could be adjusted to reach as superior as the roof of left atrium for transmural lesions. The floor line was made by linear ablation pen. The LAA was removed by stapler before PVI for better exposure of the roof.
Results:
This modified "mini-maze" was successfully completed in 53 non-paroxysmal AF patients except 1 was converted to sternotomy due to intraoperative hemorrhage. All patients recovered uneventfully. Seven-day Holter was accessed in 3, 6 and 12 months respectively in all patients. The mean follow-up was 14 (range, 3-30) months. Sinus rhythm was achieved in 48.1%, 64.8% before discharge and 3 months after surgery respectively, Twenty-eight patients in sinus rhythm or not, underwent catheter mapping and ablation three months after the operation to conform the lesion set made by this procedure. Sinus rhythm reached 87.0% after subsequent catheter ablation without any anti-arrhythmia treatment at 12 months. All patients survived without stroke, hemorrhage and pulmonary vein stenosis.
Conclusions:
Modified "mini-maze" procedure is safe, less invasive and highly reproducible for lone AF. Sequential hybrid procedure will shape the treatment of non-paroxysmal AF.
More Related Videos
06:25Cooling or Warming the Esophagus to Reduce Esophageal Injury During Left Atrial Ablation in the Treatment of Atrial Fibrillation
Published on: March 15, 2020
04:58Reduced Procedure Time and Variability with Active Esophageal Cooling During Radiofrequency Ablation for Atrial Fibrillation
Published on: August 25, 2022
Related Concept Videos
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
Amyloid Fibrils
Frustration and Conflict: Avoidance-Avoidance, Double-Approach Avoidance
Standing Waves
Fibril-associated Collagen
For example, the type II collagen fibrils in cartilage have covalently bound type IX fibril-associated collagens at regular intervals. Other types of fibril-associated collagens are...
Standing Electromagnetic Waves
Suppose a sheet of a perfect conductor is placed in the yz-plane, and a linearly polarized electromagnetic wave traveling in the...