Related Experiment Video
Updated: Jan 22, 2026

Clinical-oriented Three-dimensional Gait Analysis Method for Evaluating Gait Disorder
Published on: March 4, 2018
Evaluation of parameters obtained from two systems of gait analysis
N D Assaf1, S C Rahal1, L R Mesquita1
1Department of Veterinary Surgery and Anesthesiology, School of Veterinary Medicine and Animal Science - São Paulo State University (UNESP), Botucatu, SP, 18618970, Brazil.
Background:
The technical difficulties in utilising the force platform have stimulated the use and development of other gait systems. Therefore, this study aimed to compare the values of gait parameters obtained from a pressure-sensitive walkway and from a treadmill in healthy dogs during walking.
Methods:
Twelve healthy, privately owned, Labrador retriever dogs were used. During each trial, each dog was led across the pressure-sensitive walkway utilising a loose leash to the right of the handler. The velocity was restricted to the range of 0.9 to 1.1 m/s and the acceleration between -0.15 and 0.15 m/s2 . For the treadmill, each dog also walked with leash loose on the treadmill. The treadmill speed was maintained at 0.9m/s. The temporospatial variables, and percentage of body weight distribution/percentage of pressure were evaluated between the two gait systems.
Results:
For both forelimbs and hind limbs, significant differences were found between stance percentage, which was higher on treadmill, and swing percentage and stride length/stance distance, which were higher on the pressure-sensitive walkway. The duty factor value was 0.57 for the pressure-sensitive walkway and 0.60 for treadmill.
Clinical Relevance:
Each gait system has limitations, but also advantages that must be considered depending upon the variable and animal to be evaluated. The gait parameters obtained from the Tekscan pressure-sensitive walkway and Gait4Dog treadmill revealed differences in the temporospatial parameters between systems, but similarity in body-weight distribution/pressure percentage.
Related Concept Videos
Noncompartmental Analysis: Miscellaneous Pharmacokinetic Parameters
One key aspect of the noncompartmental approach is determining a drug's total clearance. This can be done by dividing the drug dose by the area under the concentration-time curve from zero to infinity. The area under the concentration-time curve represents the drug's...
Wave Parameters
Second Order systems II
First Order Systems
When a first-order system is subjected to a unit-step input, its response is characterized by its transfer function. By applying the Laplace transform of the unit-step input to the transfer function, expanding the...
Second Order systems I
By reinterpreting the system, one can derive the closed-loop transfer function, which...
Distributions to Estimate Population Parameter