Related Experiment Video
Updated: Jan 22, 2026

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
Quantitative T2 mapping accelerated by GRAPPATINI for evaluation of muscles in patients with myositis
Fengdan Wang1, Haiping Zhang2, Chanyuan Wu3
1Department of Radiology, Peking Union Medical College Hospital, No.1 Shuaifuyuan, Dongcheng District, Beijing, China.
Objective:
Dermatomyositis (DM) and polymyositis (PM) make up the largest group of potentially treatable myopathies and require early diagnosis. This study investigates whether the edema of thigh muscles in DM/PM can be quantitatively assessed by a novel accelerated T2 mapping technique-GRAPPATINI.
Methods:
Three conventional MR sequences and GRAPPATINI accelerated T2 mapping of bilateral thighs from 20 patients (7 DM and 13 PM) and 10 healthy volunteers were prospectively carried out on a 3 T MR scanner. Afterwards, T2 values of 477 thigh muscles from the patients and the healthy controls were manually measured. In addition, the correlations between T2 values and serum muscle enzymes in patients were also analyzed.
Results:
The new GRAPPATINI technique made quantitative T2 mapping of bilateral thighs feasible with a scanning time of only 2 min 18 s. Moreover, GRAPPATINI-generated T2 values of muscles from patients were markedly higher than those from healthy subjects (p < 0.001). GRAPPATINI accelerated T2 mapping appeared a more sensitive technique in that some DM/PM muscles appearing normal per conventional MRI had increased T2 relaxation time. Furthermore, GRAPPATINI-generated T2 values of DM/PM thigh muscles positively correlated with serum enzyme levels (p < 0.001), which reflected the severity of myopathy.
Conclusion:
GRAPPATINI can significantly shorten acquisition time of T2 mapping and may potentially be applied clinically in DM and PM.
Advances In Knowledge:
GRAPPATINI acceleration makes T2 mapping feasible in clinical practice in providing quantitative information regarding thigh muscle inflammation in DM and PM.
Related Concept Videos
Accelerators
The effectiveness of calcium chloride can...
Accelerating Fluids
The motion of the liquid within this infinitesimal cylinder is considered to obtain the pressure difference. Three vertical forces act on this liquid:
Instantaneous Acceleration
Acceleration Vectors
Average Acceleration
Measuring Acceleration Due to Gravity
A simple pendulum can be described as a point mass and a string. Meanwhile, a physical pendulum is any object whose oscillations are similar to a simple pendulum, but cannot be modeled as a point mass on a string because its mass is distributed over a larger area. The behavior of a physical pendulum can be modeled using the principles of...