Related Experiment Video
Updated: Jan 22, 2026

Extraction of Structural Extracellular Polymeric Substances from Aerobic Granular Sludge
Published on: September 26, 2016
Evaluation of extracellular polymeric substances extracted from waste activated sludge as a renewable corrosion
Liew Chien Go1, William Holmes2, Dilip Depan1
1Department of Chemical Engineering, University of Louisiana at Lafayette, Lafayette, LA, USA.
Background:
Waste activated sludge (WAS) has recently gained attention as a feedstock for resource recovery. The aim of this study is to investigate the corrosion inhibition efficiencies of extracellular polymeric substances (EPS) extracted from WAS.
Methods:
The studied corrosion inhibitors were tested with carbon steel in 3.64% NaCl saturated with CO2 at 25 °C, which is the typical oilfield environment. They were first prepared by EPS extraction (heating at 80 °C), followed by centrifugation for solid and liquid separation, then the supernatant was freeze-thawed five times for sterilization of microorganisms in WAS to terminate metabolic activities in the test inhibitors to ensure consistency in corrosion inhibition. The EPS mixture (supernatant) was then deemed as the test corrosion inhibitor. The inhibition performance was determined using potentiodynamic polarization scans.
Results:
Waste activated sludge alone showed unsatisfactory inhibition. However, EPS extracted from WAS showed an optimum inhibition of approximately 80% with 1,000 mg/L of inhibitor. The average total solid (TS) and EPS contents of the WAS were 7,330 mg TS/L WAS and 110 mg EPS/g TS, respectively. Three sets of extracted EPS were scanned with fourier-transform infrared spectroscopy (FTIR) and showed almost overlapping curves, yielding the consistent inhibition performance.
Discussion:
The potentiodynamic polarization results indicated that EPS acts as a mixed-type inhibitor which inhibits corrosion on both anode and cathode sites of metal surfaces. Based on the FTIR results, it was assumed that major chemical groups O-H, N-H, C-N, C=O, and C-H contributed to the inhibition by adsorbing on the metal surface, forming a biofilm that acts as a protective barrier to isolate the metal from its corrosive environment. Results show that WAS EPS corrosion inhibitors have inhibition performance comparable to commercial products, signifying their potential in commercialization. This corrosion inhibitor is renewable, biodegradable, non-toxic, and free from heavy metal, making it a superior green corrosion inhibitor candidate. Additionally, turning biomass into value-added product can be beneficial to the environment and, in this case, deriving new materials from WAS could also transform the economics of wastewater treatment operations.
Related Concept Videos
Corrosion
The Extracellular Matrix
Eukaryotic Transcription Inhibitors
Eukaryotic transcription inhibitors usually contain two distinct domains, a...
Corrosion of Reinforcement
However, over time and under certain conditions like carbonation, chloride ingress, and cracking this protective state can be compromised. Steel has areas with...
Deleterious Substances in Aggregate
Another type of impurity is clay and fine material that...
Substance Use Disorders Affecting Sleep
Understanding the concepts of physical dependence,...