Related Experiment Video
Updated: Jan 22, 2026

A Method for Studying the Temperature Dependence of Dynamic Fracture and Fragmentation
Published on: June 28, 2015
Open Reduction Internal Fixation of a Medial Epicondyle Avulsion Fracture With Incarcerated Fragment
James D Ostrander1, Megan OʼConnell2, Henry J Dolch3
1Ortho Michigan, Hurley Medical Center, Flint, MI.
Purpose:
The purpose of this video is to present a technique for open reduction and internal fixation of a displaced unstable medial epicondyle avulsion fracture.
Method:
A 13-year-old boy presented 2 days after injury at our institution after sustaining a medial epicondyle avulsion fracture with incarcerated fragment and posterolateral dislocation of the elbow after a fall off a fence. He described paresthesia in the ulnar nerve distribution and demonstrated slight weakness to intrinsic hand strength on examination. He was urgently reduced under sedation in the emergency department using the Roberts maneuver, a technique consisting of a valgus stress with forearm supination with finger and wrist extension that uses muscle forces to extract the fragment. Successful reduction of the ulna-humeral joint and extraction of the incarcerated medial epicondyle was demonstrated on CT. The patient was then taken in a nonurgent fashion to the operating room for open reduction and internal fixation of the displaced medial epicondyle fracture. Intraoperative examination after fixation demonstrated a congruent and stable elbow. A long-arm cast was then applied.
Results:
The video is 7-minute, 38-second duration in time and 461 MB in size.
Conclusions:
Although fixation of medial epicondyle avulsion fractures may be controversial, there are some indications for ORIF including incarcerated epicondylar fragment, suspected entrapment and dysfunction of the ulnar nerve, marked instability of the elbow, and open fracture. Presented in this video is a safe technique for ORIF of the displaced and unstable medial epicondyle avulsion fracture.
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
Related Concept Videos
Habitat Fragmentation
Internal Energy
Internal Energy
Oxidation-Reduction Reactions
Internal Receptors
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...