Related Experiment Video
Updated: Jan 22, 2026

In Vitro Thrombosis Test for Ventricular Assist Devices
Published on: March 21, 2025
Early Detection of Pump Thrombosis in Patients With Left Ventricular Assist Device
Joanna Grabska1, Thomas Schlöglhofer1,2,3, Christoph Gross1,3
1From the Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
Abstract:
Pump thrombosis (PT) is a serious adverse event in patients receiving left ventricular assist devices (LVAD). The study aims to determine whether pump parameters and clinical data may enable early detection of PT. This retrospective study included 88 patients who received an LVAD between 2012 and 2015 among which those with intra-PT were identified. In a propensity score-matched control group observation, time periods were matched with time before thrombosis. International normalized ratio (INR) time in therapeutic range (TTR) and lactate dehydrogenase (LDH) were analyzed for 60 days preceding PT. Furthermore, pump data (power, flow, and speed) in HeartWare ventricular assist devices (HVAD) patients were analyzed 7 days before PT using a mixed-design analysis of variance to investigate temporal changes in pump data. Pump thrombosis occurred in 15 patients (13 males, age 58 ± 10 years, 7 HeartMate II and 8 HVAD). International normalized ratio therapeutic range (2.0-3.0) and acetylsalicylic acid daily doses (100-200 mg) were similar for both groups, but patients with PT had lower TTR (36% vs. 65%; p = 0.025). No significant difference in LVAD power between groups was seen at baseline (p = 0.31), and power did not change in the control group over time (p > 0.99). Lactate dehydrogenase increased already 1 week prior PT and power from 4.4 ± 0.8 W at baseline to 4.9 ± 0.8 W (p = 0.007) 2 days before readmission and to 6.5 ± 1.8 W (p = 0.015) at readmission. Pump thrombosis is associated with a lower percentage of INR TTR and elevated LDH before the event. A better monitoring of pump parameters would enable PT detection already up to 2 days in advance.
Related Concept Videos
Venous Thrombosis I: Introduction
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
Venous Thrombosis III: Interprofessional Care