Objective:
To enable reliable cerebral embolic load monitoring from high-intensity transient signals (HITS) recorded with single-channel transcranial Doppler (TCD) ultrasound.
Methods:
We propose a HITS detection and characterization method using a weighted-frequency Fourier linear combiner that estimates baseline Doppler signal power. An adaptive threshold is determined by examining the Doppler signal power variance about the baseline estimate, and HITS are extracted if their Doppler power exceeds this threshold. As signatures from multiple emboli may be superimposed, we analyze the detected HITS in the time-frequency (TF) domain to segment the signals into individual emboli. A logistic regression classification approach is employed to classify HITS into emboli or artifacts. Data were collected using a commercial TCD device with emboli-detection capabilities from 12 children undergoing mechanical circulatory support or cardiac catheterization. A subset of 696 HITS were reviewed, annotated, and split into training and testing sets for developing and evaluating the HITS classification algorithm.
Results:
The classifier yielded 98% and 96% sensitivity for 100% specificity on training and testing data, respectively. The TF approach decomposed 38% of candidate embolic signals into two or more embolic events that ultimately account for 69% of the overall embolic counts. Our processing pipeline resulted in highly accurate emboli identification and produced emboli counts that were lower (by a median of 64%) compared to the commercial ultrasound system's estimates.
Significance:
Using only single-channel, single-frequency Doppler ultrasound, the proposed method enables sensitive detection and segmentation of embolic signatures. Our approach paves the way toward accurate real-time cerebral emboli monitoring.
More Related Videos
10:41Analysis of Cerebral Vasospasm in a Murine Model of Subarachnoid Hemorrhage with High Frequency Transcranial Duplex Ultrasound
Published on: June 3, 2021
09:11Embolic Middle Cerebral Artery Occlusion MCAO for Ischemic Stroke with Homologous Blood Clots in Rats
Published on: September 17, 2014
Related Concept Videos
Load-frequency control
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Pulmonary Embolism I: Introduction
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Frequency-dependent Selection