Use of Two Intracorporeal Ventricular Assist Devices As a Total Artificial Heart
Published on: May 11, 2018
Hemodynamic Effects of Mechanical Circulatory Support Devices in Ventricular Septal Defect
Mohit Pahuja1, Benedikt Schrage2, Dirk Westermann2
1Division of Cardiology, Department of Internal Medicine, Detroit Medical Center/Wayne State University Medical School of Medicine, Detroit, MI (M.P.).
Background:
Ventricular septal defect (VSD) is a lethal complication of acute myocardial infarction (AMI) and is often associated with cardiogenic shock. The optimal form of percutaneous mechanical circulatory support (MCS) for AMI-VSD is unknown.
Methods And Results:
We used a previously validated cardiovascular model to simulate AMI-VSD with parameters adjusted to replicate average hemodynamics reported in the literature, including a pulmonary-to-systemic blood flow ratio of 3.0. We then predicted effects of different types of percutaneous MCS (including intra-aortic balloon pumping, Impella, TandemHeart, and extracorporeal membrane oxygenation) on pressures and flows throughout the cardiovascular system. The simulation replicated all major hemodynamic parameters reported in the literature with AMI-VSD. Inotropes and vasopressors worsened left-to-right shunting, whereas vasodilators decreased shunting at the expense of worsening hypotension. All MCS devices increased forward blood flow and arterial pressure but other effects varied among devices. Impella 5.0 provided the greatest degree of pulmonary capillary wedge pressure reductions and decreased left-to-right shunting. Extracorporeal membrane oxygenation worsened pulmonary capillary wedge pressure and shunting, which could be improved by adding Impella or passive left ventricular vent. Pulmonary-to-systemic blood flow ratio could not be reduced below 2.0, and pulmonary flows remained high with all forms of MCS.
Conclusions:
Although no form of percutaneous MCS normalized hemodynamics in AMI-VSD, pulmonary capillary wedge pressure and shunting were worsened by extracorporeal membrane oxygenation and improved by Impella. Accordingly, based on hemodynamics alone, Impella provides the optimal form of support in AMI-VSD. However, other factors, including team experience, device availability, potential for tissue ingestion, and clinical characteristics, need to be considered when choosing a percutaneous MCS device for AMI-VSD.
More Related Videos
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
05:36Standardized Model of Ventricular Fibrillation and Advanced Cardiac Life Support in Swine
Published on: January 30, 2020
Related Concept Videos
Anatomy of the Circulatory System
Self-Help Support Groups
Accessibility and Cost-Effectiveness
One of the primary strengths of self-help...
Lumber Defects
Shakes are minor fractures that run along or across the wood's annual rings, while wane is...
Buffer Effectiveness
The buffer capacity is the amount of acid or base that can be added to a given volume...
Support Reactions
The purpose of the supports is to prevent the translational motion of the system by applying an equal and opposite force and to prevent the system's rotation by applying...
Blood Pressure Imbalances and Circulatory Shock
Blood Pressure: Hypertension and Hypotension
Normal blood pressure is 120/80 mm Hg. Elevated blood pressure is 120-129/under 80 mm Hg. Hypertension, warranting treatment at 130/80 mm Hg, is often asymptomatic and can lead to severe cardiovascular events, aneurysms, peripheral arterial disease, chronic renal disease, or cardiac...