Aim:
To assess prostate magnetic resonance imaging (MRI) image quality and compliance with technical standards between centres in the South West region of the UK.
Materials And Methods:
Fifteen imaging sites in the region submitted seven consecutive anonymised MRI studies. These were assessed by two experienced radiologists in consensus. Overall, subjective image quality for T2-weighted imaging (T2W), diffusion weighted imaging (DWI), and dynamic contrast enhancement (DCE) was scored on a five-point Likert scale. Five additional quality parameters were also assessed visually, including image noise, motion, artefact, and distortion. The degree of compliance by each site with 21 published technical standards was also assessed.
Results:
Ninety-four MRI examinations were reviewed from across all sites (mean 6.3 scans per site, range 5-7). Mean compliance with technical standards was 63% (range 38-86%). Forty-seven percent of sites did not perform DCE. One site used a 3 T scanner. The percentage of patients with overall quality scores of ≥3 (diagnostically acceptable) were 68% for T2W, 81% for DWI, and 60% for both T2W and DWI. Ninety-three percent of the 45 patients who underwent DCE had diagnostically acceptable studies. By scanner age, the percentage of patients with diagnostically acceptable T2W scores was 53% for scanners ≥7 years and 80% when <7 years (p=0.006). Comparing individual sites, the mean overall quality scores were 2.9 (range 2.2-4.2) for T2W, 3.2 (1.8-4.7) for DWI, and 3.4 (2.5-4.7) for DCE.
Conclusion:
There is wide variation in compliance with recognised technical standards and image quality across sites. If MRI is to replace biopsy in selected low-risk patients, improvements in image quality may be required.
Insights
Prostate MRI image quality and adherence to technical standards vary significantly across UK sites. Improvements are needed for MRI to potentially replace biopsies in low-risk patients.
Area of Science:
- Radiology
- Medical Imaging
- Urology
Background:
- Prostate magnetic resonance imaging (MRI) is increasingly important for diagnosing and managing prostate cancer.
- Standardized technical protocols are crucial for ensuring consistent and reliable MRI image quality.
Purpose of the Study:
- To evaluate the consistency of prostate MRI image quality and adherence to technical standards across different imaging centers in the UK's South West region.
- To identify variations in image quality and compliance that may impact diagnostic accuracy.
Main Methods:
- Fifteen imaging sites submitted anonymized prostate MRI studies (T2-weighted imaging (T2W), diffusion-weighted imaging (DWI), and dynamic contrast enhancement (DCE)).
- Two radiologists assessed subjective image quality (Likert scale) and objective parameters (noise, motion, artifact, distortion).
- Compliance with 21 published technical standards was evaluated for each site.
Main Results:
- Mean compliance with technical standards was 63%, with significant site variation (38-86%).
- Forty-seven percent of sites did not perform DCE; only one site used a 3T scanner.
- Diagnostically acceptable image quality (≥3 Likert score) was achieved for 68% (T2W), 81% (DWI), and 60% (T2W/DWI combined).
- Older scanners (≥7 years) showed lower T2W image quality compared to newer scanners (p=0.006).
Conclusions:
- There is substantial variability in prostate MRI technical standard compliance and image quality among UK centers.
- To support the potential use of MRI as a replacement for biopsy in select low-risk patients, enhancements in image quality and standardization are necessary.
More Related Videos
10:19Getting to Compliance in Forced Exercise in Rodents: A Critical Standard to Evaluate Exercise Impact in Aging-related Disorders and Disease
Published on: August 22, 2014
06:04Surgical Treatment for Benign Prostatic Hyperplasia: Holmium Laser Enucleation of the Prostate HoLEP.
Published on: March 6, 2018
Related Concept Videos
Internal Energy
Internal Energy
Internal Receptors
Measurement: Standard Units
International System of Units
Prefixes are used to define both larger and smaller quantities in the SI system. For example, milli, micro, and nano define smaller quantities, while kilo, mega, and giga are used to define...
Quality of Water