Related Experiment Video
Updated: Jan 22, 2026

Author Spotlight: Studying Brain Endothelial Barrier in Metastatic Cancer Using Impedance-Based Biosensors
Published on: September 22, 2023
APPLICATION OF TIME-AVERAGED AND INTEGRAL-BASED MEASURE FOR MEASUREMENT RESULTS VARIABILITY REDUCTION IN GSM/DCS/UMTS
Darko Šuka1, Predrag Pejović2, Mirjana Simić-Pejović2
1University of East Sarajevo, Faculty of Electrical Engineering, East Sarajevo, Bosnia and Herzegovina.
Abstract:
Since EMF levels from wireless telecommunication networks are non-stationary and exhibit large temporal variations, the use of continuous measurements during extended periods (preferably 24 h or longer) with a data-logging system is required. Because of the short-term variations of E field, the 6-min measurements and 6-min averaged results to obtain the mean level strength at a given place appear to be dependent on the time of measurements during the day. This paper presents a new (integral-based) measure to evaluate electromagnetic exposure. The new measure is a pure physical descriptor of the amount of exposed energy density (a parameter accumulated from instantaneous power density values in time). To confirm previous observations, continuous measurements with personal exposure metre were recorded 24 h a day for two weeks at every location in urban area, 14 different locations in total. Additionally, to check temporal variations and repeatability of exposure assessment, a week of prolonged measurements was taken 6 months later, making in total three weeks of measurements at 2 locations. Day-to-day repeatability of RF-EMF exposure was analysed through the time-averaged and integral-based measure. The analysis is based on approximately 5.1 million data samples (1.7 million for each band). The ratio between the maximum and minimum instantaneous (maximum and minimum 6-min averaged) E field values during the day could reach up to 25 dB (20 dB). Therefore, great variability in the results may occur. By applying the 24 h time-averaged and integral-based measure on a 24 h data set of measurements, the variability of daily exposure could stay within ±20% of the week mean level obtained either with the time-averaged or integral-based measure. Both, the time-averaged E field and integral-based power density exposures of the general public in all locations were found to be well below the general public exposure limits of the ICNIRP guidelines.
Related Concept Videos
Multi-input and Multi-variable systems
In the absence of...
Control Systems: Applications
In modern vehicles, control systems manage various functions to enhance performance and safety. The steering wheel and accelerator are primary inputs in a car's control system. The...
Application of Integration: Problem Solving
Measurement: Standard Units
The Integrated Rate Law: The Dependence of Concentration on Time
Measuring Reaction Rates

