CONE BEAM CT IN DENTAL IMPLANT PLANNING: HOW CLOSE ARE PATIENT DOSIMETRY RESULTS WITH DATA FROM PHANTOM STUDIES FOUND
S Kottou1, A Zapros2, N Stefanopoulou3
1National and Kapodistrian University of Athens, School of Medicine, Medical Physics Lab, Athens, Greece.
Abstract:
Advantages of Cone Beam Computed Tomography (CBCT) include high-quality 3D imaging and reduced radiation exposure with relatively low cost. In this study, patient radiation exposure in CBCT implant planning dentistry was measured in terms of Kerma Area Product (KAP). Data were obtained from 217 CBCT scans on 168 individuals using a CS9300 Carestream system. Scans were made using 80-90 kVp, 4-5 mA, 8 and 13.3 s exposure time (depending on voxel size) and a fixed field of view (FOV) of 10 × 10 cm2 (medium). Mean KAP was estimated using two voxel sizes 180 × 180 × 180 μm3 and 200 × 200 × 200 μm3 and found to be 399 and 314 mGycm2, respectively. Corresponding KAP values found in literature ranged between 210 and 2140 mGycm2. Mean E was estimated using conversion coefficient factors found in literature, according to FOV size and tube voltage value and found to range between 24 and 161 μSv.
More Related Videos
08:41Patient-Specific Polyvinyl Alcohol Phantom Fabrication with Ultrasound and X-Ray Contrast for Brain Tumor Surgery Planning
Published on: July 14, 2020
09:57Development and Evaluation of 3D-Printed Cardiovascular Phantoms for Interventional Planning and Training
Published on: January 18, 2021
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Nursing Process for Patient and Caregiver Teaching II: Planning and Implementation
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...