Abstract:
The objective of this study was to develop a mouthpiece sensor with improved head kinematic measurement for use in non-helmeted and helmeted sports through laboratory validation and pilot field deployment in female youth soccer. For laboratory validation, data from the mouthpiece sensor was compared to standard sensors mounted in a headform at the center of gravity as the headform was struck with a swinging pendulum. Linear regression between peak kinematics measured from the mouthpiece and headform showed strong correlation, with r2 values of 0.95 (slope = 1.02) for linear acceleration, 1.00 (slope = 1.00) for angular velocity, and 0.97 (slope = 0.96) for angular acceleration. In field deployment, mouthpiece data were collected from four female youth soccer players and time-synchronized with film. Film-verified events (n = 915) were observed over 9 practices and 5 games, and 632 were matched to a corresponding mouthpiece event. This resulted in an overall sensitivity of 69.2% and a positive predictive value of 80.3%. This validation and pilot field deployment data demonstrates that the mouthpiece provides highly accurate measurement of on-field head impact data that can be used to further study the effects of impact exposure in both helmeted and non-helmeted sports.
More Related Videos
07:30A Test Bed to Examine Helmet Fit and Retention and Biomechanical Measures of Head and Neck Injury in Simulated Impact
Published on: September 21, 2017
08:07Author Spotlight: Advancing Traumatic Brain Injury Research - A Closed-Head Model for Accurate Replication and Rapid Assessment
Published on: September 22, 2023
Related Concept Videos
Reliability and Validity
Pilot and Numeric Relaying
In Vitro Drug Release Testing: Overview, Development and Validation
Impact of Groups on Groups
Muscles that Move the Head
The bilateral sternocleidomastoid, or SCM, and the suprahyoid and infrahyoid muscles are significant head flexors. The SCM muscles originate at the sternum and clavicle and attach to the mastoid process of the temporal bone. The SCM contracts bilaterally to bend the head forward, whereas...
Impact
When particles with different initial velocities collide, they induce deformation by applying equal and opposite impulses. At the point of maximum deformation, the particles move together with...