Lumpectomy Specimen Radiography: Does Orientation or 3-Dimensional Tomosynthesis Improve Margin Assessment?
Julia Mario1, Shambhavi Venkataraman2, Valerie Fein-Zachary2
1Harvard Medical School, Boston, Massachusetts, USA.
Two orthogonal views of breast cancer specimens improved margin assessment over a single view, though not always significantly. Three-dimensional tomosynthesis did not enhance margin assessment compared to 2D mammography.
Area of Science:
- Radiology
- Surgical Pathology
- Medical Imaging
Background:
- Accurate surgical margin assessment is crucial for effective breast cancer treatment.
- Current methods for evaluating excised breast cancer specimens have limitations in precision.
Purpose of the Study:
- To evaluate if two orthogonal views of breast cancer specimens improve surgical margin assessment compared to a single view.
- To determine if 3D tomosynthesis enhances surgical margin assessment over 2D mammography.
Main Methods:
- Forty-one breast cancer specimens were prospectively imaged using four protocols: single 2D view (1VSU), two orthogonal 2D views (2VSU), two orthogonal 2D views on a mammogram unit (2V2DMU), and two orthogonal 3D images (2V3DMU).
- Three breast imagers independently assessed surgical margins for all specimens.
- Histopathology served as the gold standard for margin status.
Main Results:
- The area under the curve (AUC) for diagnostic accuracy was 0.60 (1VSU), 0.66 (2VSU), 0.68 (2V2DMU), and 0.60 (2V3DMU).
- Two orthogonal views (2VSU) showed improved accuracy over a single view (1VSU), with statistical significance for one reader.
- 3D tomosynthesis (2V3DMU) showed mixed results compared to 2D mammography (2V2DMU), with decreased accuracy for two readers.
Conclusions:
- Two orthogonal views of excised breast cancer specimens offer improved accuracy for surgical margin assessment compared to a single view.
- Three-dimensional tomosynthesis does not appear to improve surgical margin assessment compared to standard 2D mammography.
More Related Videos
Related Concept Videos
Margin of Error
Location and Orientation of the Heart
Dimensional Analysis
Conversion Factors and Dimensional Analysis
The unit...
Dimensional Analysis
In fluid mechanics, dimensional...
Methods of Documentation I: Source-Oriented Records
In an SOR, each discipline involved in patient care maintains a separate medical record section. This record-keeping method enables easy tracking of patient progress and ensures healthcare staff have access to up-to-date information.
Key Attributes include the following:
ortho–para-Directing Activators: –CH3, –OH, –⁠NH2, –OCH3