Related Experiment Video
Updated: Jan 22, 2026

Simple and Fast Rolling Circle Amplification-Based Detection of Topoisomerase 1 Activity in Crude Biological Samples
Published on: December 2, 2022
Integration of rolling circle amplification and optomagnetic detection on a polymer chip
Francesca Garbarino1, Gabriel Antonio S Minero1, Giovanni Rizzi1
1Department of Health Technology, Technical University of Denmark, DTU Health Tech, Building 345C, DK-2800, Kongens Lyngby, Denmark.
Abstract:
Rolling circle amplification (RCA) combined with padlock probe recognition of a DNA target is attractive for on-chip nucleic acid testing due to its high specificity and isothermal reaction conditions. However, the integration of RCA on an automated chip platform is challenging due to the different reagents needed for the reaction steps and the temperature sensitivity of the phi29 polymerase. Here, we describe the integration of an RCA assay on a single-use polymer chip platform where magnetic microbeads are used as solid support to transport the DNA target between three connected reaction chambers for (i) padlock probe annealing and ligation, (ii) RCA, and (iii) optomagnetic detection of RCA products. The three chambers were loaded with reagents by sequential filling combined with passive microfluidic structures. After loading, the on-chip assay steps were automated. For an assay in which all steps but the padlock probe annealing on the target were performed on-chip, we found a limit of detection (LOD) for a synthetic influenza target of 2 pM after 45 min of RCA, which is comparable to the corresponding laboratory assay. The entire assay, including padlock probe annealing, could be performed on-chip with an LOD of 20 pM after 45 min of RCA. This LOD can likely be reduced by further optimizing the microbead mixing. The results present important steps towards the integration and automation of RCA and potentially also other complex multi-step assays on a single-use polymer chip for molecular analysis.
More Related Videos
14:12Amplification of Escherichia coli in a Continuous-Flow-PCR Microfluidic Chip and Its Detection with a Capillary Electrophoresis System
Published on: November 21, 2023
10:51Fabrication and Validation of an Organ-on-chip System with Integrated Electrodes to Directly Quantify Transendothelial Electrical Resistance
Published on: September 26, 2017
Related Concept Videos
Polymers
Rolling Without Slipping
Rolling With Slipping
An object's rolling motion is characterized by its rotation around its axis, while linear motion refers to the object's translational motion along a surface. Frictional forces can...
Rolling Resistance
For instance, imagine a hard cylinder rolling on a comparatively soft surface. The cylinder's weight compresses the surface beneath it. As the cylinder moves, the material in front of it slows down due to...
Mohr's Circle for Moments of Inertia: Problem Solving
Consider a rectangular beam. The moments of inertia of the beam about the x and y axis are 2.5(107) mm4 and 7.5(107) mm4, respectively. The product of inertia is 1.5(107) mm4. Determine the principal moments of inertia and the orientation of the major and...
Mohr's Circle for Plane Stress
Consider a set of Cartesian coordinates. The horizontal and vertical axes correspond to normal stress (σ) and shearing stress (τ), respectively. Two points, points A and B, are defined by the normal and shear...