Development of a multiplex fully automated assay for rapid quantification of CD4+ T cells from whole blood

Mazhar Sher1, Waseem Asghar2

  • 1Asghar-Lab, Micro and Nanotechnology in Medicine, College of Engineering and Computer Science, Boca Raton, FL, 33431, USA; Department of Computer & Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, FL, 33431, USA.

The development of cost-effective and rapid assays for the accurate counting of CD4 cells has remained prime focus for disease management. The lack of such assays has severely affected people living in resource-limited disease prevalent areas. CD4 count information plays a vital role in the effective management of HIV disease. There is an unmet need to develop rapid, cost-effective, portable and user-friendly point-of-care (POC) disease diagnostic platform technology for CD4+ T cell counting. Here, we have developed a flow-free magnetic actuation platform that uses antibody-coated magnetic beads to efficiently capture CD4+ T cells from a 30 μL drop of whole blood. On-chip cell lysate electrical impedance spectroscopy has been utilized to quantify the isolated CD4 cells. The developed assay has a limit of detection of 25 cells per μL and provides accurate CD4 counts in the range of 25-800 cells per μL. The whole immunoassay along with the enumeration process is very rapid and provides CD4 quantification results within 5 min time frame. The assay does not require off-chip sample preparation steps and minimizes human involvement to a greater extent. The developed impedance-based immunoassay has potential to significantly improve the CD4 enumeration process especially for POC settings.

Related Concept Videos

Development of Blood Vessels01:07

Development of Blood Vessels

The development of the vascular system in a fetus is a complex and intricate process that begins as early as 15 to 16 days post-conception. This process starts outside the embryo, specifically in the mesoderm of the yolk sac, chorion, and connecting stalk. Approximately two days later, the formation of blood vessels occurs within the embryo itself.
The initial formation of this system is facilitated by the small amount of yolk present in the ovum and yolk sac. Blood vessels originate from...
1.4K
Protein Buffers in Blood Plasma and Cells01:20

Protein Buffers in Blood Plasma and Cells

The human body utilizes protein buffer systems to maintain a stable pH. These systems capitalize on the dual role of amino acids, which can act as acids or bases by accepting or releasing hydrogen ions in response to pH changes. Protein buffer systems are particularly significant in the extracellular fluid (ECF) and intracellular fluid (ICF) of active cells, where structural and functional proteins provide substantial buffering capacity.
Certain amino acids can exist in a zwitterion state at a...
3.7K
Zygotic Development And Stem Cell Formation01:10

Zygotic Development And Stem Cell Formation

The development of all multicellular organisms starts with the fusion of haploid cells called sperm and egg to form a diploid zygote. A zygote is a totipotent cell that can develop into a complete organism. The zygote undergoes cell division or cleavage to form an 8-cell mass. Until this stage, the cells are spherical, loosely attached, and remain totipotent. Totipotent cells are capable of developing both the embryonic and the extraembryonic tissues. However, as they continue to divide, they...
6.6K
Sustainable Development01:43

Sustainable Development

As the human population continues to grow and use resources, we must be mindful of our planet’s natural limits. Sustainable development provides a pathway to maintain and improve human life now while also ensuring that future generations will have the resources that they need. The long-term success of sustainability efforts rests on understanding the interplay between human actions and ecological systems.
14.8K
Distribution Reliability and Automation01:25

Distribution Reliability and Automation

Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
498
Rapidly Varying Flow01:24

Rapidly Varying Flow

Rapidly varying flow (RVF) in open channels is characterized by abrupt changes in flow depth over a short distance, with the rate of depth change relative to distance often approaching unity. These flows are inherently complex due to their transient and multi-dimensional nature, making exact analysis difficult. However, approximate solutions using simplified models provide valuable insights into their behavior.Key Features of Rapidly Varying FlowRVF is commonly observed in scenarios involving...
462