Feasibility evaluation of non-invasive cardiac function technology during echocardiography-based cardiac stress
Davinder Ramsingh1, Michael Ma2, Jin Kyung Kim3
1Department of Anesthesiology & Perioperative Care, Loma Linda University Medical Center, 11234 Anderson Street, MC-2532-D, Loma Linda, CA, 92354, USA. dramsingh@llu.edu.
Abstract:
Evaluation of cardiac function during periods of stress is of key importance for the perioperative setting. Non-invasive hemodynamic monitors provide markers of cardiac function. This pilot study sought to evaluate the ability of a non-invasive hemodynamic monitor to detect cardiac stress during formal stress echocardiography testing. The primary goal was to compare the change in hemodynamic values during the pre/during/post phases of stress echocardiography testing in patients who had results negative versus positive for myocardial ischemia. Adult patients scheduled for outpatient cardiac stress testing were screened. Only patients scheduled for stress-echocardiography testing were consented. Patients with history of arrhythmias were excluded. During the testing, patients wore a cuff-based hemodynamic sensor (Nexfin system, Edwards Lifesciences). Data from the hemodynamic sensor were compared to the findings of the stress study. A total of 37 patients were enrolled, with 31 patients included for analysis. Five patients had stress studies positive for coronary ischemia. Comparison of the hemodynamic variables between patients who had a positive stress study versus negative showed a significant reduction in the percentage change in dP/dt and stroke volume from baseline (p < 0.05). This pilot study indicates that patients who have abnormal stress echocardiograms also have significantly reduced values from a noninvasive hemodynamic monitor. Further evaluation of the clinical utility of this technology, to assist in the care of patients at risk for cardiac ischemia, should be carried out.
More Related Videos
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac Cycle
During the cardiac cycle, blood flow through the heart is regulated entirely by changing pressure gradients. This sequence of events begins with the heart in a state of total relaxation, known as mid-to-late diastole, during which blood passively flows from...
The Cardiac Cycle
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...