Related Experiment Video
Updated: Jan 22, 2026

Vascular Gene Transfer from Metallic Stent Surfaces Using Adenoviral Vectors Tethered through Hydrolysable Cross-linkers
Published on: August 12, 2014
Prospective Evaluation of the TIGRIS Vascular Stent Within a Modern Treatment Algorithm
Martin Werner1, Fatemeh Gomari-Grisar1, Silvia Belalcazar1
1Department of Angiology, Hanusch Krankenhaus, Vienna, Austria.
Abstract:
Purpose: To prospectively evaluate the safety and efficacy of the TIGRIS Vascular Stent in the superficial femoral artery (SFA) and proximal popliteal artery within a treatment algorithm that reserved stent usage for more challenging patients. Materials and Methods: This prospective, single-center study enrolled 97 patients (mean age 68.7 years; 66 men) who were treated for 100 de novo or nonstented restenotic femoropopliteal lesions (≥70% stenosis) and had recoil or dissection after plain balloon predilation. The average lesion length was 5.6±2.3 cm (maximum 8 cm per protocol). The composite primary efficacy outcome was 12-month primary patency, defined as a peak systolic velocity ratio ≤2.5 at the stented target lesion on duplex ultrasound, and no clinically-driven reintervention within the stented segment. The primary safety outcome was freedom from device- and procedure-related target vessel revascularization, target limb major amputation (above the metatarsals), or death through 30 days. Secondary outcomes included secondary patency, clinically-driven target lesion revascularization (TLR), Rutherford category change relative to baseline, and binary restenosis of the target lesion. Results: All devices were successfully implanted with no device-related complications at the time of implant or within the 30-day postimplant window. The average stented length was 7.0±2.5 cm; no stent elongation was observed during deployment. One patient was lost to follow-up before 12 months and another died of an unrelated cause, leaving 95 patients (98 lesions) available for 12-month follow-up and 77 patients/lesions for the 24-month preliminary analysis. The binary primary and secondary patency rates at 12 months were 92.9% and 100%. The binary freedom from TLR was 94.9%. At 24 months, the Kaplan-Meier estimate of primary patency was 90.0%. Conclusion: This prospective study demonstrated that the TIGRIS Vascular Stent is a safe and effective device in a modern treatment algorithm that reserved bare stent use for postangioplasty dissection or recoil in distal femoropopliteal arteries.
More Related Videos
Related Concept Videos
Modern Molecular Taxonomy
Trial and Error and Algorithm
Seedless Vascular Plants
Vascular Spasm
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...
Vascular Resistance
The primary determinants of vascular resistance are vessel diameter, blood viscosity, and vessel length. Among these, vessel diameter plays the most significant role due to the fourth power relationship described by...