Related Experiment Video
Updated: Jan 22, 2026

Structure of HIV-1 Capsid Assemblies by Cryo-electron Microscopy and Iterative Helical Real-space Reconstruction
Published on: August 9, 2011
Automatic current selection with iterative reconstruction reduces effective dose to less than 1 mSv in low-dose chest
Li-Guo Chen1, Ping-An Wu, Min-Huei Sheu
1Department of Radiology, Buddhist Tzu Chi General Hospital, Hualien, Taiwan, ROC.
Abstract:
Most of the recent studies have used fixed tube current while few investigators use automatic current selection (ACS) with iterative reconstruction (IR) techniques to reduce effective dose (ED) to < 1 mSv in low-dose chest computed tomography (LDCCT). We investigated whether image quality of lungs as produced by a fixed tube current (FTC) of 35 mAs can be maintained with ED < 1 mSv produced by ACS with IR techniques in LDCCT. A total of 32 participants were included. The LDCCT was performed by a FTC 35 mAs (with a kilovoltage peak of 120 kVp) in 16 participants (Group A), and by a DoseRight ACS in 16 participants (Group B). Their images were improved by IR technique. The ED was estimated by multiplying the individual dose length product (DLP) by the dose conversion factor. The image quality was assessed by the CT number, noise levels, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of the regions of interest in the apex, upper lobe, and lower lobe of lung regions in the CT images. A t-test was used to evaluate the LDCCT image quality between the groups. The ED was significantly 49.2% lower in Group B than in Group A (0.71 ± 0.05 mSv vs 1.40 ± 0.02 mSv, P < .001). However, noise level, SNR, and CNR were not significantly different between Groups A and B, indicating the image quality was similar between two groups, or our setting parameters for DoseRight ACS with IR technique can achieve the image quality as good as obtained on the FTC 35 mAs with IR techniques. Our results suggest that the DoseRight ACS with IR technique reduces ED to lower than 1 mSv (averagely 0.71 mSv) yet maintains an image quality as good as produced by FTC 35 mAs with IR technique in normal BMI persons. The ACS setup thus is more preferable than the FTC to achieve the ALARA (as low as reasonably achievable) principle.
Related Concept Videos
Dose-Response Relationship: Selectivity and Specificity
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
Dose-Response Relationship: Overview

