Related Experiment Video
Updated: Jan 22, 2026

Extracting Metrics for Three-dimensional Root Systems: Volume and Surface Analysis from In-soil X-ray Computed Tomography Data
Published on: April 26, 2016
Comparison of orthodontic root resorption of root-filled and vital teeth using micro-computed tomography
Objective:
To evaluate the difference in orthodontic root resorption between root-filled and vital teeth.
Material And Methods:
Sixteen individuals who required bilateral premolar tooth extraction due to orthodontic treatment and had a previously root-filled premolar tooth on one side were included in the study. The experimental group consisted of root-filled premolar teeth, and the control group consisted of contralateral vital premolar teeth. A 150-g buccally directed force was applied to these teeth using 0.017 × 0.025-inch TMA cantilever springs. The premolars were extracted 8 weeks after the application of force. Images were obtained using micro-computed tomography. Resorption measurements were obtained using the Image J program.
Results:
The mean values for resorption were 0.08869 mm3 for the root-filled teeth and 0.14077 mm3 for the contralateral teeth, indicating significantly less resorption for the root-filled teeth compared with the contralateral teeth after the application of orthodontic force (P = .003). In both groups, the most resorption was seen on the cervical-buccal and apical-lingual surfaces. The mean resorption value of the cervical region was 0.06305 mm3 in the control group and 0.0291 mm3 in the experimental group, and the difference was statistically significant (P = .002).
Conclusions:
Root-filled teeth showed significantly less orthodontic root resorption than vital teeth.
Related Concept Videos
Primary and Secondary Growth in Roots and Shoots
Root Mean Square
For example, consider the velocity of gas molecules in a container. The gas molecules are moving in different directions, which might impart positive and negative...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Root-Locus Method
This system can be represented by a block...
Construction of Root Locus
For positive gain values, the root locus exists on the real axis to the left of an odd number of finite open-loop poles or zeros. The root locus starts at the open-loop poles and traces the paths of the closed-loop poles as the gain...
Properties of the Root Locus
To determine if a point lies on the root locus, the criterion involves the sum of angles contributed by all poles and zeros to that point. Specifically, this sum must be an odd multiple of 180 degrees. The gain at any point on...

