Dual pitch titanium-coated pedicle screws improve initial and early fixation in a polyetheretherketone rod semi-rigid fixation system in sheep
Related Experiment Video
Updated: Jan 22, 2026

C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
Published on: September 16, 2022
Wen-Tao Wang1,2, Chi-Hua Guo2, Kun Duan3
1Department of Orthopedics, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi 710054, China.
Background:
Reports on the efficacy of modifications to the thread design of pedicle screws are scarce. The aim of the study was to investigate initial and early fixation of pedicle screws with a plasma-sprayed titanium coating and dual pitch in the pedicle region (dual pitch titanium-coated pedicle screw [DPTCPS]) in a polyetheretherketone (PEEK) rod semi-rigid fixation system.
Methods:
Fifty-four sheep spine specimens and 64 sheep were used to investigate initial ("0-week" controls) and early (post-operative 6 months) fixation, respectively. Sheep were divided into dual pitch pedicle screw (DPPS), standard pitch pedicle screw (SPPS), DPTCPS, and standard pitch titanium-coated pedicle screw (SPTCPS) groups. Specimens/sheep were instrumented with four screws and two rods. Biomechanical evaluations were performed, and histology at the implant-bone interface was investigated.
Results:
At 0-week, mean axial pull-out strength was significantly higher for the DPTCPS and SPTCPS than the SPPS (557.0 ± 25.2 vs. 459.1 ± 19.1 N, t = 3.61, P < 0.05; 622.6 ± 25.2 vs. 459.1 ± 19.1 N, t = 3.43, P < 0.05). On toggle-testing, the DPTCPS was significantly more resistant than the SPPS and SPTCPS (343.4 ± 16.5 vs. 237.5 ± 12.9 N, t = 3.52, P < 0.05; 343.4 ± 16.5 vs. 289.9 ± 12.8 N, t = 3.12, P < 0.05; 124.7 ± 13.5 vs. 41.9 ± 4.3 cycles, t = 2.18, P < 0.05; 124.7 ± 13.5 vs.79.5 ± 11.8 cycles, t = 2.76, P < 0.05). On cyclic loading, maximum displacement was significantly lower for the DPTCPS than the SPPS and SPTCPS (1.8 ± 0.13 vs. 3.76 ± 0.19 mm, t = 2.29, P < 0.05; 1.8 ± 0.13 vs. 2.46 ± 10.20 mm, t = 2.69, P < 0.05). At post-operative 6 months, mean axial pull-out strength was significantly higher for the DPTCPS and SPTCPS than the SPPS (908.4 ± 33.6 vs. 646.5 ± 59.4 N, t = 3.34, P < 0.05; 925.9 ± 53.9 vs. 646.5 ± 59.4 N, t = 3.37, P < 0.05). On toggle-testing, the DPTCPS was significantly more resistant than the SPPS and SPTCPS (496.9 ± 17.9 vs. 370.3 ± 16.4 N, t = 2.86, P < 0.05; 496.9 ± 17.9 vs. 414.1 ± 12.8 N, t = 2.74, P < 0.05; 249.1 ± 11.0 vs.149.9 ± 11.1 cycles, t = 2.54, P < 0.05; 249.1 ± 11.0 vs.199.8 ± 7.2 cycles, t = 2.61, P < 0.05). On cyclic loading, maximum displacement was significantly lower for the DPTCPS than the SPPS and SPTCPS (0.96 ± 0.11 vs. 2.39 ± 0.14 mm, t = 2.57, P < 0.05; 0.96 ± 0.11 vs. 1.82 ± 0.12 mm, t = 2.73, P < 0.05). Resistance to toggle testing (370.3 ± 16.4 vs. 414.1 ± 12.8 N, t = 3.29, P < 0.05; 149.9 ± 11.1 vs.199.8 ± 7.2 cycles, t = 2.97, P < 0.05) was significantly lower and maximum displacement in cyclic loading (2.39 ± 0.14 vs.1.82 ± 0.12 mm; t = 3.06, P < 0.05) was significantly higher for the SPTCPS than the DPTCPS. Bone-to-implant contact was significantly increased for the DPTCPS compared to the SPPS (58.3% ± 7.0% vs. 36.5% ± 4.4%, t = 2.74, P < 0.05); there was no inflammatory reaction or degradation of coated particles.
Conclusion:
DPTCPSs might have stronger initial and early fixation in a PEEK rod semi-rigid fixation system.
Related Concept Videos
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Carbon-dioxide Fixation
Initiation of Translation
First, the initiator tRNA must be selected from the pool of elongator tRNAs by eukaryotic initiation factor 2 (eIF2). The initiator tRNA (Met-tRNAi) has conserved sequence elements including modified bases at...
Initiation of Translation
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Screw: Problem Solving
To evaluate the...