Related Experiment Video
Updated: Jan 22, 2026

A Novel Non-invasive Method for the Detection of Elevated Intra-compartmental Pressures of the Leg
Published on: May 31, 2019
Intra-Abdominal Hypertension Is Responsible for False Negatives to the Passive Leg Raising Test
Alexandra Beurton1,2, Jean-Louis Teboul1,2, Valentina Girotto1
1Service de médecine intensive-réanimation, Hôpital de Bicêtre, Hôpitaux universitaires Paris-Sud, Assistance publique - Hôpitaux de Paris, Le Kremlin-Bicêtre, France.
Objectives:
To compare the passive leg raising test ability to predict fluid responsiveness in patients with and without intra-abdominal hypertension.
Design:
Observational study.
Setting:
Medical ICU.
Patients:
Mechanically ventilated patients monitored with a PiCCO2 device (Pulsion Medical Systems, Feldkirchen, Germany) in whom fluid expansion was planned, with (intra-abdominal hypertension+) and without (intra-abdominal hypertension-) intra-abdominal hypertension, defined by an intra-abdominal pressure greater than or equal to 12 mm Hg (bladder pressure).
Interventions:
We measured the changes in cardiac index during passive leg raising and after volume expansion. The passive leg raising test was defined as positive if it increased cardiac index greater than or equal to 10%. Fluid responsiveness was defined by a fluid-induced increase in cardiac index greater than or equal to 15%.
Measurements And Main Results:
We included 60 patients, 30 without intra-abdominal hypertension (15 fluid responders and 15 fluid nonresponders) and 30 with intra-abdominal hypertension (21 fluid responders and nine fluid nonresponders). The intra-abdominal pressure at baseline was 4 ± 3 mm Hg in intra-abdominal hypertension- and 20 ± 6 mm Hg in intra-abdominal hypertension+ patients (p < 0.01). In intra-abdominal hypertension- patients with fluid responsiveness, cardiac index increased by 25% ± 19% during passive leg raising and by 35% ± 14% after volume expansion. The passive leg raising test was positive in 14 patients. The passive leg raising test was negative in all intra-abdominal hypertension- patients without fluid responsiveness. In intra-abdominal hypertension+ patients with fluid responsiveness, cardiac index increased by 10% ± 14% during passive leg raising (p = 0.01 vs intra-abdominal hypertension- patients) and by 32% ± 18% during volume expansion (p = 0.72 vs intra-abdominal hypertension- patients). Among these patients, the passive leg raising test was negative in 15 patients (false negatives) and positive in six patients (true positives). Among the nine intra-abdominal hypertension+ patients without fluid responsiveness, the passive leg raising test was negative in all but one patient. The area under the receiver operating characteristic curve of the passive leg raising test for detecting fluid responsiveness was 0.98 ± 0.02 (p < 0.001 vs 0.5) in intra-abdominal hypertension- patients and 0.60 ± 0.11 in intra-abdominal hypertension+ patients (p = 0.37 vs 0.5).
Conclusions:
Intra-abdominal hypertension is responsible for some false negatives to the passive leg raising test.
Related Concept Videos
False Memories
One primary source of false memories is misattribution, where individuals incorrectly associate external information...
Muscles that Move the Leg
Anterior Compartment
The quadriceps femoris, the most visible muscle of the anterior compartment, is integral for leg extension and thigh flexion. It is formed by merging four distinct muscles — the vastus lateralis, vastus medialis, vastus intermedius, and rectus femoris. The quadriceps tendon, a shared tendon of the four quadriceps muscles, is affixed...
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Active versus Passive Immunity
Active Immunity
Active immunity refers to the resistance one develops...
Abdominal Aorta
The celiac trunk, a singular artery, divides into the left gastric artery, which...
Negative Regulator Molecules

