Related Experiment Video
Updated: Jan 22, 2026

Optic Nerve Sheath Point of Care Ultrasound: Image Acquisition
Published on: August 18, 2023
Optimal timing to measure optic nerve sheath diameter as a prognostic predictor in post-cardiac arrest patients
Jung Soo Park1, Yongchul Cho2, Yeonho You2
1Department of Emergency Medicine, Chungnam National University Hospital, 282, Munhwa-ro, Jung-gu, Daejeon, Republic of Korea; Department of Emergency Medicine, College of Medicine, Chungnam National University School of Medicine, 282, Mokdong-ro, Jung-gu, Daejeon, Republic of Korea.
Aim:
We evaluated the optimal timing of optic nerve sheath diameter (ONSD) measurement to predict neurologic outcome in post-cardiac arrest patients treated with target temperature management (TTM).
Methods:
This was a prospective single-centre observational study from April 2018 to March 2019. Good outcome was defined as the Glasgow-Pittsburgh cerebral performance categories (CPC) 1 or 2, and poor outcome as a CPC between 3 and 5. ONSD was measured initially after return of spontaneous circulation (ROSC) (ONSDinitial), at 24 h (ONSD24), 48 h (ONSD48), and 72 h (ONSD72) using ultrasonography. The receiver operating characteristic (ROC) curves and DeLong method were used to compare the values for predicting neurologic outcomes.
Results:
Out of the 36 patients enrolled, 18 had a good outcome. ONSD24, ONSD48, and ONSD72 were higher in the poor outcome group. The area under ROC curve of ONSD24 was 0.91 (95% confidence interval 0.77-0.98) in predicting poor neurologic outcomes. With a cut off value of 4.90 mm, ONSD24 had a sensitivity of 83.3% and a specificity of 94.4% in predicting poor neurologic outcomes.
Conclusion:
Our findings demonstrate ONSD24 as a valuable tool to predict the neurologic outcome in post-cardiac arrest patients treated with TTM. Therefore, we recommend performing ONSD measurement using ultrasonography at 24 h after ROSC, rather than immediately after ROSC, to predict neurologic outcome in post-cardiac arrest patients treated with TTM.
More Related Videos
06:43Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs
Published on: July 12, 2022
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Cardiac Catheterization IV: Nursing Management
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Design Example: Calculating Safe Diameter for Wind-Exposed Disc
Optimal Foraging