A three-dimensional cross-directional bilateral filter for edge-preserving noise reduction of low-dose computed
Katsuhiro Ichikawa1, Hiroki Kawashima1, Masato Shimada2
1Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, 920-0942, Japan.
Background:
Image-based noise reduction techniques are useful because they can be applied across various computed tomography (CT) scanner models from different vendors, regardless of the iterative reconstruction availability. The purpose of this study was to propose a 3-dimensional cross-directional bilateral filter (3D-CDBF) and compare the edge-preserving noise reduction on low-dose CT images to a model-based iterative reconstruction (MBIR).
Methods:
The 3D-CDBF comprises a bilateral filter and a smoothing filter applied in range filtering. The filtering process was applied with four iterations using empirically determined parameters that yielded the best tradeoff between noise reduction and edge preservation for a very low radiation dose of 2.5 mGy. In-plane and z-directional edge preservation performances for low-contrast rod phantoms (60 Hounsfield units) were compared to a clinically available MBIR and a conventional 3D bilateral filter (3D-BF), using task-based spatial resolution (task-based transfer function: TTF) and slice thickness. Moreover, the noise power spectra (NPS) were compared. Furthermore, performance was compared on abdominal CT images acquired from volunteers at 2.5 mGy (approved by our institutional review board).
Results:
In phantom tests, 3D-CDBF provided 28.5% higher spatial resolution at 50%TTF compared to MBIR. Moreover, total NPS was lower, while the slice thickness (z-axis resolution) was slightly broader than that achieved by MBIR (0.99 mm vs. 0.92 mm). 3D-BF was inferior to both 3D-CDBF and MBIR in all measurements. Consistent with phantom results, 3D-CDBF significantly reduced noise on abdominal images compared to MBIR (P < 0.001), exhibiting better preservation of organ edges.
Conclusion:
This 3D-CDBF may provide superior edge preserving noise reduction of low-dose CT images compared to currently available MBIR.
More Related Videos
13:10Combined Near-infrared Fluorescent Imaging and Micro-computed Tomography for Directly Visualizing Cerebral Thromboemboli
Published on: September 25, 2016
11:49Using High Resolution Computed Tomography to Visualize the Three Dimensional Structure and Function of Plant Vasculature
Published on: April 5, 2013
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Crossing Over
The homologous pairs of sister chromosomes—one from the maternal and one from the paternal genome—then begin to align alongside each other lengthwise, matching corresponding DNA positions in a process...
Crossed Aldol Reaction Using Strong Bases: Directed Aldol Reaction
Oxidation-Reduction Reactions