Introduction:
The small size of a nidus and the extensive sclerosis around it often make it difficult to identify tumors from the surrounding normal bone by fluoroscopy, and a large amount of bone resection might be required to secure complete removal during osteoid osteoma surgery. In this report, we present the first case of radiographically invisible osteoid osteoma that was successfully resected under a robotic C-arm cone-beam computed tomography (CBCT) imaging system.
Presentation Of Case:
A 14-year-old boy presented with persistent pain around the left knee joint was diagnosed with osteoid osteoma of the left distal femur. Since the tumor was not detectable by intraoperative fluoroscopy, a CBCT system was used for guidance during an open tumor resection. For a less invasive surgery, we repurposed the dilator and retractor of the microendoscopic discectomy (MED) system and resected the tumor using the wider trephine tips for bone biopsy. At the final follow-up one year later, the function of the afflicted limb was normal with no complaint of any symptoms. Plain radiograph at the final follow-up showed new bone formation completely filling the bone defect, without local recurrence.
Discussion:
CBCT allowed for clear intraoperative visualization of the osteoid osteoma, thereby promising a secure resection and less invasive osteoid osteoma treatment. Furthermore, the repurposed use of the dilator and retractor of the MED system as well as the wider trephine tips for bone biopsy made the procedure less invasive.
Conclusion:
CBCT-guided minimally invasive open excision surgery could be a useful option for the management of radiographically invisible osteoid osteoma.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
08:34Optimizing Minimally Invasive Spine Surgery: A Fully 3D CT O-Arm Navigated Workflow in MIS TLIF
Published on: October 17, 2025
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Base Excision Repair
The first step of...
Base Excision Repair
Nucleotide Excision Repair
Nucleotide Excision Repair
Cells are regularly exposed to mutagens—factors in the environment that can damage DNA and generate mutations. UV radiation is one of the most common mutagens and is estimated to introduce a significant number of changes in DNA. These include bends or kinks in the structure, which can block DNA replication or transcription. If these errors are not fixed, the damage can cause mutations, which in turn can result in cancer or disease depending on which sequences are...