Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Published on: June 7, 2015
Anatomical deformation due to horizontal rotation: towards gantry-free radiation therapy
J G Buckley1,2,3, R Rai2,4, G P Liney1,5,2,4
1Centre For Medical Radiation Physics, University of Wollongong, NSW, Australia.
Abstract:
Gantry-free radiation therapy systems may be simpler and more cost effective, particularly for MRI-guided photon or hadron therapy. This study aims to understand and quantify anatomical deformations caused by horizontal rotation with scan sequences sufficiently short to facilitate integration into an MRI-guided workflow. Rigid and non-rigid pelvic deformations due to horizontal rotation were quantified for a cohort of 8 healthy volunteers using a bespoke patient rotation system and a clinical MRI scanner. For each volunteer a reference scan was acquired at 0° followed by sequential faster scans in 45° increments through to 360°. All fast scans were registered to the 0° image via a three-step process: first, images were aligned using MR visible couch markers. Second, the scans were pre-processed then rigidly registered to the 0° image. Third, the rigidly registered scans were non-rigidly registered to the 0° image to assess soft tissue deformation. The residual differences after rigid and non-rigid registration were determined from the transformation matrix and the deformation vector field, respectively. The rigid registration yielded mean rotations of ⩽2.5° in all cases. The average 3D translational magnitudes range was 5.8 ± 2.9 mm-30.0 ± 11.0 mm. Translations were most significant in the left-right (LR) direction. Smaller translations were observed in the anterior-posterior (AP) and superior-inferior (SI) directions. The maximum deformation magnitudes range was: 10.0 ± 0.9 mm-28.0 ± 2.8 mm and average deformation magnitudes range: 2.3 ± 0.6 mm-7.5 ± 1.0 mm. Average non-rigid deformation magnitude was correlated with BMI (correlation coefficient 0.84, p = 0.01). Rigid pelvic deformations were most significant in the LR direction but could be accounted for with on-line adjustments. Non-rigid deformations can be significant and will need to be accounted for in order to facilitate the delivery of gantry-free therapy with an automated patient rotation system.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Related Concept Videos
Biological Effects of Radiation
Plastic Deformations
Plastic Deformations
Introduction to Horizontal Curves
Horizontal Curve: Problem Solving
Horizontal Gene Transfer