Costs and complications of endovascular inferior vena cava filter retrieval

Anand Brahmandam1, Laura Skrip2, Hamid Mojibian3

  • 1Section of Vascular Surgery, Department of Surgery, Yale University School of Medicine, New Haven, Conn.

Insights

Advanced endovascular retrieval (AER) for inferior vena cava (IVC) filters is effective but significantly more costly and complex than standard retrieval (SR). AER procedures are associated with higher complication rates, longer procedure times, and increased fluoroscopy use.

Area of Science:

  • Vascular Surgery
  • Interventional Radiology
  • Health Economics

Background:

  • Inferior vena cava (IVC) filters are used to prevent pulmonary embolism.
  • Retrieval of IVC filters can be challenging, often requiring advanced endovascular techniques.
  • The comparative cost-effectiveness of different IVC filter retrieval methods has not been well-established.

Purpose of the Study:

  • To compare the procedural costs of standard retrieval (SR) versus advanced endovascular retrieval (AER) for IVC filters.
  • To analyze the factors influencing the costs and outcomes of IVC filter retrieval techniques.

Main Methods:

  • Retrospective review of 191 consecutive IVC filter retrievals (2009-2014).
  • Classification of procedures into Standard Retrieval (SR) and Advanced Endovascular Retrieval (AER).
  • Comparison of patient characteristics, procedural details, complications, and hospital costs between SR and AER groups.

Main Results:

  • Advanced endovascular retrieval (AER) was associated with significantly higher procedural costs ($14,565 ± $6354) compared to standard retrieval (SR) ($7644 ± $2810).
  • AER procedures had higher complication rates (20.6% vs 5.2%), longer fluoroscopy times, and longer total procedural times.
  • AER was more likely to be used in cases with prior retrieval attempts.

Conclusions:

  • Advanced endovascular techniques are a feasible option for challenging IVC filter retrievals.
  • These advanced techniques are associated with significantly higher procedural costs and a higher rate of complications compared to standard retrieval.
  • The increased cost and complication rate must be considered when selecting IVC filter retrieval strategies.
Abstract

Related Concept Videos

Retrieval01:12

Retrieval

Retrieval is the process of getting information out of memory storage and back into conscious awareness. This ability is essential for daily tasks like brushing hair and teeth, driving to work, and performing job duties. Retrieval occurs in three ways: recall, recognition, and relearning.
Recall involves accessing information without cues, such as during an essay test, where individuals must retrieve facts and concepts from memory unaided. Another example is remembering the name of a colleague...
423
Passive Filters01:27

Passive Filters

Passive filters are utilized to shape the frequency spectrum of signals across a diverse array of applications. These filters, using only passive elements like resistors (R), inductors (L), and capacitors (C), are capable of selectively allowing or blocking certain frequency ranges without the need for external power sources.
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
964
ER Retrieval Pathway01:45

ER Retrieval Pathway

In the secretory pathway, vesicles transport proteins from one cellular compartment to another in forward transport to deliver the protein to its correct location. Occasionally, misfolded proteins and incorrect proteins escape their original compartments, and a retrieval pathway is used to return the escaped proteins to their original compartment.
The ER uses many checkpoints to prevent the entry of incorrectly folded or a resident protein as cargo onto a transport vesicle. These mechanisms...
4.7K
Active Filters01:25

Active Filters

Active filters are electronic circuits that use operational amplifiers (op-amps), resistors, and capacitors to filter out unwanted frequency components from a signal. A first-order low-pass active filter is designed to pass signals with a frequency lower than a certain cutoff frequency and attenuate frequencies higher than that cutoff frequency. The transfer function for a first-order low-pass active filter is:
1.3K
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
705
Diabetes: Symptoms, Diagnosis, and Complications01:15

Diabetes: Symptoms, Diagnosis, and Complications

For most patients, experiencing several weeks of polyuria, polydipsia, fatigue, and significant weight loss may indicate the presence of diabetes. Furthermore, adults displaying the phenotypic appearance of type 2 diabetes (particularly those who are obese and not initially insulin-requiring), may have islet cell autoantibodies, suggesting autoimmune-mediated β cell destruction and a diagnosis of latent autoimmune diabetes of adults (LADA). The categorization of glucose homeostasis is...
2.1K