Related Experiment Video
Updated: Jan 22, 2026

Evaluation of Capillary and Other Vessel Contribution to Macular Perfusion Density Measured with Optical Coherence Tomography Angiography
Published on: February 18, 2022
Immediate effects of smoking on optic nerve and macular perfusion measured by optical coherence tomography
Maksym Ciesielski1, Piotr Rakowicz1, Marcin Stopa2
1Department of Ophthalmology, Chair of Ophthalmology and Optometry Heliodor Swiecicki University Hospital, Poznan University of Medical Sciences, 60-780, ul. Grunwaldzka 16/18, Poznan, Poland.
Abstract:
The aim of this study was the assessment of the relationship between cigarette smoking and optic nerve and macular vessel density measured by optical coherence tomography angiography. We examined 30 eyes from 30 healthy habitual smokers. The examination was performed using a high-speed and high-resolution spectral-domain optical coherence tomography RTVue XR Avanti with AngioVue (Optovue, Fremont, CA, USA) with a split-spectrum amplitude-decorrelation angiography algorithm. Blood pressure, heart rate, vascular density in the area of the optic nerve head (4.5*4.5 mm) and vascular density with the foveal avascular zone in the central macula (3.0*3.0 mm) were measured and analyzed before, immediately after and 30 minutes after cigarette smoking. Quantitative measurements were carried out by AngioAnalytics Phase 7 software. Immediately after smoking both heart rate and blood pressure increased significantly (p < 0.001) compared to values before smoking and then significantly decreased after 30 minutes comparing to values obtained right after smoking (p < 0.001). The mean area of the foveal avascular zone, parafoveal vessel density, and peripapillary vessel density did not change significantly. Our results show no immediate influence of smoking on vessel density parameters measured by specific OCTA machine in healthy habitual smokers.
Related Concept Videos
Properties of Enantiomers and Optical Activity
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Buffer Effectiveness
The buffer capacity is the amount of acid or base that can be added to a given volume...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Biological Effects of Radiation
Framing Effects

