The Safety of Maternal and Fetal MRI at 3 T

Andre L Chartier1,2, Monique J Bouvier1, Danielle R McPherson1

  • 1Department of Radiology, Naval Medical Center San Diego, 34800 Bob Wilson Dr, Ste 204, San Diego, CA 92134.

OBJECTIVE. The purpose of this study was to evaluate the effects of clinical 3-T MRI during pregnancy on fetal growth and neonatal hearing in neonates at low risk of congenital hearing impairment or of brain or chromosomal abnormalities. MATERIALS AND METHODS. This single-center retrospective case-control study included consecutively born healthy neonates exposed in utero to 3-T MR during MRI for maternal or fetal indications and born between January 2008 and March 2015. Each exposed neonate was randomly matched 1:2 by birth date to healthy control neonates who had not been exposed to MR. Infant birth weights were compared by unpaired t test. Hearing impairment between groups was compared by Fisher exact test. RESULTS. There was no significant difference in mean birth weight between the MR-exposed (3398 g) and control (3510 g) neonates (p = 0.06). There was no significant difference in prevalence of hearing impairment (p = 0.55) between the MR-exposed (0% [0/81]) and control (1.8% [3/162]) groups. CONCLUSION. This study showed no adverse effects with regard to neonatal hearing or fetal growth in healthy neonates who were variably exposed to 3-T MR in utero during MRI for various clinical maternal or fetal indications at any gestational age.

Related Concept Videos

Survey Safety01:28

Survey Safety

Surveying near highways, rough terrain, or power lines involves significant risks. Working along highways is particularly dangerous and requires the use of warning signs and flagmen. It is safest to avoid working directly on roads and use offsets whenever possible. When highway work is unavoidable, it must follow all safety guidelines. Surveyors should wear bright clothing, such as orange reflective vests, to ensure visibility to motorists, coworkers, and hunters. In construction zones, wearing...
374
Fetal Circulation01:14

Fetal Circulation

Fetal circulation is a unique system that facilitates the exchange of gases, nutrients, and waste products between the developing fetus and the mother. This intricate process takes place through a special organ called the placenta.
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
2.7K
Household Wiring And Electrical Safety01:13

Household Wiring And Electrical Safety

Companies that supply power to most modern households use three conductors, typically called a three-wire line. While one is neutral, the other two are both at 120 V but with opposite polarity, giving a voltage of 240 V between them. With a three-wire line, high-power appliances that require 240 V, such as electric stoves and clothes dryers, are linked between the two hot lines. 120 V appliances can be connected between the neutral and either of the hot lines. The neutral side, which is always...
1.6K
Imaging Studies I: CT and MRI01:14

Imaging Studies I: CT and MRI

Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
835
ortho–para-Directing Activators: –CH3, –OH, –⁠NH2, –OCH301:11

ortho–para-Directing Activators: –CH3, –OH, –⁠NH2, –OCH3

All ortho–para directors, excluding halogens, are activating groups. These groups donate electrons to the ring, making the ring carbons electron-rich. Consequently, the reactivity of the aromatic ring towards electrophilic substitution increases. For instance, the nitration of anisole is about 10,000 times faster than the nitration of benzene. The electron-donating effect of the methoxy group in anisole activates the ortho and para positions on the ring and stabilizes the corresponding...
7.3K
Radiological Investigation II: MRI and Ventilation Perfusion Scan01:30

Radiological Investigation II: MRI and Ventilation Perfusion Scan

Description
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
556