Prosthesis-Patient Mismatch after Surgical Aortic Valve Replacement: Neither Uncommon nor Harmless
Sérgio da Costa Rayol1,2, Michel Pompeu Barros Oliveira Sá1,2,3, Luiz Rafael Pereira Cavalcanti1,2
1Pronto-Socorro Cardiológico de Pernambuco Department of Cardiovascular Surgery Recife PE Brazil Department of Cardiovascular Surgery at Pronto-Socorro Cardiológico de Pernambuco (PROCAPE), Recife, PE, Brazil.
Abstract:
Prosthesis-patient mismatch (PPM) after surgical aortic valve replacement (SAVR) is an issue that has been overlooked (not to say neglected). Cardiac surgeons must bear in mind that this is a real problem that we must tackle. The purpose of this paper is to be a wake-up call to the surgical community by giving a brief overview of what PPM is, its incidence and impact on the outcomes. We also discuss the increasing role played by imaging for predicting and assessing PPM after SAVR (with which surgeons must become more acquainted) and, finally, we present some options to avoid PPM after the surgical procedure.
More Related Videos
Related Concept Videos
Mismatch Repair
Mismatch Repair
The Mutator Protein Family Plays a Key Role in DNA Mismatch Repair
The human genome has more than 3 billion base pairs of DNA per cell. Prior to cell division, that vast amount of genetic...
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Continuous Renal Replacement Therapy
Mitral Valve Prolapse I: Introduction
Aortic Regurgitation I: Introduction