Development of a novel customized cutting and rotating template for Bernese periacetabular osteotomy
Xuyi Wang1,2, Shixian Liu3, Jianping Peng2
1Department of Orthopaedics, The First Affiliated Hospital of Bengbu Medical College, Bengbu, Anhui, China.
Background:
Bernese periacetabular osteotomy (PAO) has been shown to be applicable as a hip-preserving technique for the treatment of developmental dysplasia of the hip (DDH). The approach could be designed preoperatively using various types of reverse-engineering software and finite element analysis, but how to implement it in the actual PAO remains a challenge. This study examines and evaluates a solution to achieve higher accuracy when performing a PAO.
Methods:
A patient-specific cutting and rotating template was predesigned through computer-aided design (CAD) with three-dimensional (3D) modeling programs. The templates were then reproduced with rapid prototyping (RP) technology and used in the actual PAO. Finally, the clinical and radiographic effects were assessed and compared between the newly developed PAO and conventional PAO groups.
Results:
The customized cutting template fit well with the bone surface and served as a guide for surgeons as they slid the osteotome to the precise location that had been determined prior to surgery. A very similar acetabular fragment was reproduced, and no major complications occurred when performing the osteotomy along the edge of the cutting template. The acetabular fragment was then corrected to the predetermined position through one-off manipulation with the customized rotating template. The final position of the acetabular fragment in the new developed PAO group was highly consistent with the planned position, and the postoperative morphological parameters were consistent with the preoperative planned data compared to the conventional PAO group. The duration of the operation and the number of irradiation decreased significantly. The Harris hip score (HHS) and visual analogue scale (VAS) score improved significantly with the use of the new developed PAO.
Conclusions:
We demonstrate that our system, which was based on CAD-RP technology, is feasible and could realize the predicted results accurately during the actual PAO.
More Related Videos
08:15Three-Dimensional Preoperative Virtual Planning in Derotational Proximal Femoral Osteotomy
Published on: February 17, 2023
05:45Author Spotlight: Exploring Regeneration in Axolotls Through Insights in Cellular and Molecular Mechanisms, Bone Healing, and Implications for Human Therapies
Published on: April 12, 2024
Related Concept Videos
DNA as a Genetic Template
DNA as a Genetic Template
Kinematic Equations for Rotation
For instance, imagine a point A on a rigid body engaged in circular motion. The translational velocity of this particular point can be calculated by taking the time derivatives of the displacement equation, which essentially measures the...
Cut-off Frequency of BJT
Alpha Cut-Off Frequency: Pertinent to the common-base configuration, the alpha cut-off frequency defines the upper-frequency limit at which the current gain, alpha, remains stable. As...
Brick Cutting Techniques
Cut bricks are categorized by size. Bricks cut to half their original length are called half-bats, while those cut to three-fourths their length are known as three-fourth bats.
Special types of...
Rotation of Asymmetric Top
The relationship between the angular momentum of any rigid body and its angular velocity, both of which are vectors, involves the moment of inertia. The moment of inertia is a scalar quantity only for spherically symmetric...