Related Experiment Video
Updated: Jan 22, 2026

The Role of Indocyanine Green Fluorescence in Complex Laparoscopic Cholecystectomy Navigation
Published on: January 31, 2025
3D laparoscopy does not reduce operative duration or errors in day-case laparoscopic cholecystectomy: a randomised
Katie E Schwab1,2,3, Nathan J Curtis4,5, Martin B Whyte6
1Minimal Access Therapy Training Unit, University of Surrey, Daphne Jackson Road, Guildford, UK. katschwab@doctors.org.uk.
Background:
Contemporary 3D platforms have overcome past deficiencies. Available trainee and laboratory studies suggest stereoscopic imaging improves performance but there is little clinical data or studies assessing specialists. We aimed to determine whether stereoscopic (3D) laparoscopic systems reduce operative time and number of intraoperative errors during specialist-performed laparoscopic cholecystectomy (LC).
Methods:
A parallel arm (1:1) randomised controlled trial comparing 2D and 3D passive-polarised laparoscopic systems in day-case LC using was performed. Eleven consultant surgeons that had each performed > 200 LC (including > 10 3D LC) participated. Cases were video recorded and a four-point difficulty grade applied. The primary outcome was overall operative time. Subtask time and the number of intraoperative consequential errors as identified by two blinded assessors using a hierarchical task analysis and the observational clinical human reliability analysis technique formed secondary endpoints.
Results:
112 patients were randomised. There was no difference in operative time between 2D and 3D LC (23:14 min (± 10:52) vs. 20:17 (± 9:10), absolute difference - 14.6%, p = 0.148) although 3D surgery was significantly quicker in difficulty grade 3 and 4 cases (30:23 min (± 9:24), vs. 18:02 (± 7:56), p < 0.001). No differences in overall error count was seen (total 47, median 1, range 0-4 vs. 45, 1, 0-3, p = 0.62) although there were significantly fewer 3D gallbladder perforations (15 vs. 6, p = 0.034).
Conclusion:
3D laparoscopy did not reduce overall operative time or error frequency in laparoscopic cholecystectomies performed by specialist surgeons. 3D reduced Calot's dissection time and operative time in complex cases as well as the incidence of iatrogenic gallbladder perforation (NCT01930344).
Related Concept Videos
Trial and Error and Algorithm
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Fundamental Attribution Error
Random Error
Margin of Error
Clinical Trials
There are four phases in a clinical trial. A phase one...

