A new urine assay accurately detects opioids and their metabolites in neonates. This rapid, sensitive test uses small samples, improving diagnosis of Neonatal Abstinence Syndrome (NAS).
Area of Science:
- Clinical Chemistry
- Biomedical Diagnostics
- Forensic Toxicology
Background:
- The ongoing opioid epidemic significantly impacts neonates, leading to Neonatal Abstinence Syndrome (NAS).
- Current diagnostic methods for neonatal opioid exposure are limited by poor assay performance, false-negatives, and insufficient sample volumes.
- Rapid and sensitive testing is crucial for timely NAS diagnosis and management.
Purpose of the Study:
- To develop and validate a novel, small-volume urine assay for quantifying opioids and their metabolites.
- To assess the assay's sensitivity, specificity, and accuracy compared to existing methods like LC-MS/MS and immunoassays.
- To explore the potential of this assay for noninvasive opioid screening in neonates and pharmacokinetic tracking.
Main Methods:
- Development of a free-solution assay (FSA) utilizing high-affinity DNA aptamer probes.
- Integration of a compensated interferometric reader (CIR) for sensitive detection.
- Quantification of oxycodone, hydrocodone, fentanyl, and their urinary metabolites in small urine volumes (10 μL).
Main Results:
- The FSA demonstrated excellent limits of detection (LODs) and quantification (LOQs) for target opioids and metabolites.
- The assay exhibited 5- to 275-fold higher sensitivity than LC-MS/MS and 50- to 1250-fold higher sensitivity than immunoassays.
- Accurate quantification (>95% specificity) was achieved in approximately 1 hour, with concentrations ranging from 28-81 pg/mL.
Conclusions:
- The developed FSA offers a highly sensitive, rapid, and noninvasive method for opioid quantification using minimal urine samples.
- This assay holds significant potential for improving the diagnosis and management of Neonatal Abstinence Syndrome (NAS).
- The technology could facilitate widespread opioid screening and enable precise pharmacokinetic tracking in clinical settings.