Related Experiment Video
Updated: Jan 22, 2026

Author Spotlight: A Stable Phantom Material for Optical and Acoustic Imaging
Published on: June 16, 2023
Evaluating HIFU-mediated local drug release using thermal strain imaging: Phantom and preliminary in-vivo studies
Fu-Feng Lee1, Qiong He1, Jing Gao1
1Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, 100084, China.
Purpose:
High-intensity focused ultrasound (HIFU)-mediated drug release becomes a promising therapeutic technique for treatment of cancer, which has merits of deep penetration, noninvasive approach and nonionizing radiation. However, conventional thermocouple-based approach for treatment monitoring would encounter big challenges such as the viscous heating artifact and difficulty in monitoring in the deep region. In this study, we develop an effective method based on thermal strain imaging (TSI) for the evaluation of HIFU-mediated drug release.
Methods:
Both phantom experiments and preliminary animal experiments were performed to investigate the feasibility of the proposed approach. Doxorubicin (DOX)-loaded cerasomes (HIFU and temperature-sensitive cerasomes, HTSCs) were prepared. In the phantom experiments, the HTSC solution is contained inside a cylindrical chamber within a tissue-mimicking phantom. In the animal experiments, the HTSCs are intravenously injected into tumor-bearing mice. An HIFU transducer is used to trigger DOX release from the HTSCs within the phantom or mice, and TSI is performed during HIFU heating. In the phantom experiments, the accuracy of temperature estimation using TSI is validated by measuring with a thermocouple. In animal experiments, the spatial consistency between the distribution of DOX released within the tumor and the location of the heating region estimated by TSI is validated using a spectrofluorophotometer.
Results:
In the phantom experiments, the HTSCs show a burst release of DOX when the temperature of the HTSC solution estimated by TSI reaches about 42°C, which is in agreement with the condition for drug release from the HTSCs. The temperature estimation using TSI has high accuracy with error below 2.5%. In animal experiments, fluorescence imaging of the tumor validates that the heating region of HIFU could be localized by the low-strain region of TSI.
Conclusion:
The present framework demonstrates a reliable and effective solution to the evaluation of HIFU-mediated local drug delivery.
More Related Videos
08:59Use of a Multi-compartment Dynamic Single Enzyme Phantom for Studies of Hyperpolarized Magnetic Resonance Agents
Published on: April 15, 2016
09:53The Preparation of Chicken Ex Ovo Embryos and Chorioallantoic Membrane Vessels as In Vivo Model for Contrast-Enhanced Ultrasound Imaging and Microbubble-Mediated Drug Delivery Studies
Published on: February 9, 2021
Related Concept Videos
Thermal Strain
Antiepileptic Drugs: Modulators of Neurotransmitter Release Mediated by SV2A Protein
SV2A is a transmembrane glycoprotein located predominantly in the brain, modulating the release of neurotransmitters for neuronal communication. Both levetiracetam and brivaracetam exhibit a high affinity for...
Drugs Affecting Neurotransmitter Release or Uptake
Tissue-Drug Binding: Localization of Drugs and its Significance
Drugs can bind to different tissue components, enhancing their distribution and localization. The factors influencing drug localization in tissues include the drug's lipophilicity, structural characteristics, tissue perfusion rate, and pH differences. These factors determine...
In Vitro Drug Release Testing: Overview, Development and Validation
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...