Investigation of Multi-Plane Scheme for Compensation of Fringe Effect of Electrical Resistance Tomography Sensor
Wenbin Tian1,2, Xiaofeng Liang1, Xiaolei Qu1,2
1School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China.
Abstract:
Conventional electrical resistance tomography (ERT) sensors suffer from the fringe effect, i.e., severe distortion of the electric field on both ends of the measurement electrodes, leading to a 3D sensing region for a 2D sensor. As a result, the objects outside an ERT sensor plane affect the sensing and hence image, i.e., deteriorating the image quality. To address this issue, a multiple-plane ERT sensor scheme is proposed in this paper. With this scheme, auxiliary sensor planes are used to provide references for the fringe effect of the measurement plane, for compensation by subtracting the weighed influence of the fringe effect. Simulation results show that the proposed scheme, either three-plane or two-plane sensor, can compensate for the fringe effect induced by objects outside the measurement plane with a variety of axial object distributions, i.e., several non-conductive bars or conductive bars placed at different cross-sectional and axial positions inside the sensor. Experiments were carried out. Images obtained with single-plane and multiple-plane ERT sensors are compared, and the proposed compensation scheme has been hence verified.
More Related Videos
05:56Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
Related Concept Videos
Dosage Compensation
In addition to sexual development, the X chromosome has genes involved in autosomal functions such as brain development and the immune system. Therefore, males and females with distinct numbers of X chromosomes will...
The Z-Scheme of Electron Transport in Photosynthesis
Compensation Mechanisms
Respiratory Compensation
This mechanism addresses metabolic-induced pH imbalances by adjusting breathing rates. Respiratory compensation begins within minutes of detecting a pH...
Work Done Over an Inclined Plane
The work done by gravity to move a rigid body, or the work done by an opposing force to move a rigid body against gravity, can be calculated using the center-of-mass framework. It is the line integral of the force of gravity over the path, considered positive if...
Body Planes
The sagittal plane is the plane that divides the body or an organ vertically into right and left sides. If this vertical plane runs directly down the middle of the body resulting in equal division, it is called the midsagittal or median...
Transformation of Plane Stress