Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Angular Momentum: Single Particle01:10

Angular Momentum: Single Particle

7.6K
Angular momentum is directed perpendicular to the plane of the rotation, and its magnitude depends on the choice of the origin. The perpendicular vector joining the linear momentum vector of an object to the origin is called the “lever arm.” If the lever arm and linear momentum are collinear, then the magnitude of the angular momentum is zero. Therefore, in this case, the object rotates about the origin such that it lies on the rim of the circumference defined by the lever arm...
7.6K
Scanning Electron Microscopy01:07

Scanning Electron Microscopy

5.3K
A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
5.3K
Angular Momentum01:21

Angular Momentum

768
Angular momentum characterizes an object's rotational motion and is defined as the moment of its linear momentum about a specified point O. When a particle moves along a curved path in the x-y plane, the scalar formulation calculates the magnitude of its angular momentum, utilizing the moment arm (d), representing the perpendicular distance from point O to the line of action of the linear momentum. Despite being scalar in formulation, angular momentum is inherently a vector quantity. Its...
768
Angular Velocity and Displacement01:08

Angular Velocity and Displacement

22.4K
Uniform circular motion is motion in a circle at a constant speed. Although this is the simplest case of rotational motion, it is very useful for many situations and is used to introduce rotational variables. When a particle is moving in a circle, the coordinate system is fixed and serves as a frame of reference to define the particle’s position. Its position vector from the origin of the circle to the particle sweeps out the angle θ, which increases in the counterclockwise direction...
22.4K
Conservation of Angular Momentum01:09

Conservation of Angular Momentum

15.9K
A system's total angular momentum remains constant if the net external torque acting on the system is zero. Considering a system that consists of n tiny particles, the angular momentum of any tiny particle may change, but the system's total angular momentum would remain constant. The principle of conservation of angular momentum only considers the net external torque acting on the system. While there are internal forces exerted by different particles within the system that also produce...
15.9K
Trial and Error and Algorithm01:12

Trial and Error and Algorithm

399
A problem-solving strategy is a plan of action used to find a solution. Different strategies have distinct action plans. Trial and error involves trying different solutions until one works. For instance, to fix a broken printer, you might check ink levels, ensure the paper tray isn't jammed, and verify the printer's connection to your laptop. This method can be time-consuming but is commonly used. Thomas Edison, for example, used trial and error to find a suitable filament for the light...
399

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Oxygen-Assisted MOCVD Growth of Monolayer PtSe<sub>2</sub> Films With Bandgap Opening for Semiconducting FET Channels.

Advanced science (Weinheim, Baden-Wurttemberg, Germany)·2026
Same author

Computational stability analysis suggests binding-independent destabilization in pathogenic FBXO11 variants.

Scientific reports·2026
Same author

Experimental structural characterization of reflection matrices of scattering media.

Biomedical optics express·2026
Same author

Functional impact of the ATP1A3-p.A813V variant: insights into a calcium-driven hyperexcitability cascade in rapid-onset dystonia-Parkinsonism.

Journal of translational medicine·2026
Same author

Physics-consistent denoising of full-field photoacoustic displacement maps using an adaptive residual attention network.

Photoacoustics·2026
Same author

Herpes simplex virus 1 harboring poly(T) DNA sequences as a key ligand for AIM2 inflammasome activation and host defense.

Nature communications·2026

Related Experiment Video

Updated: Jan 22, 2026

A Rapid and Chemical-free Hemoglobin Assay with Photothermal Angular Light Scattering
05:18

A Rapid and Chemical-free Hemoglobin Assay with Photothermal Angular Light Scattering

Published on: December 7, 2016

10.1K

Label-free neuroimaging in vivo using synchronous angular scanning microscopy with single-scattering accumulation

Moonseok Kim1,2,3,4, Yonghyeon Jo1,2, Jin Hee Hong1,2

  • 1Center for Molecular Spectroscopy and Dynamics, Institute for Basic Science, Seoul, 02841, Korea.

Nature Communications
|July 19, 2019
PubMed
Summary
This summary is machine-generated.

Researchers developed a new imaging technique that allows for clear, non-invasive observation of deep brain structures in living organisms without the need for fluorescent labels or physical tissue removal. By recording how light interacts with biological samples and using a specialized mathematical algorithm to filter out noise and blur, this method provides high-resolution views of complex neural networks in zebrafish. This advancement overcomes previous limitations caused by light scattering in thick tissues, enabling more accurate studies of biological systems in their natural state.

Keywords:
optical imagingzebrafish hindbraininterferometric recordingtissue turbidity

Frequently Asked Questions

More Related Videos

Label-Free Imaging of Lipid Storage Dynamics in Caenorhabditis elegans using Stimulated Raman Scattering Microscopy
10:59

Label-Free Imaging of Lipid Storage Dynamics in Caenorhabditis elegans using Stimulated Raman Scattering Microscopy

Published on: May 28, 2021

4.7K
Simultaneous Label-Free Autofluorescence Multi-Harmonic Microscopy
09:19

Simultaneous Label-Free Autofluorescence Multi-Harmonic Microscopy

Published on: August 29, 2025

587

Related Experiment Videos

Last Updated: Jan 22, 2026

A Rapid and Chemical-free Hemoglobin Assay with Photothermal Angular Light Scattering
05:18

A Rapid and Chemical-free Hemoglobin Assay with Photothermal Angular Light Scattering

Published on: December 7, 2016

10.1K
Label-Free Imaging of Lipid Storage Dynamics in Caenorhabditis elegans using Stimulated Raman Scattering Microscopy
10:59

Label-Free Imaging of Lipid Storage Dynamics in Caenorhabditis elegans using Stimulated Raman Scattering Microscopy

Published on: May 28, 2021

4.7K
Simultaneous Label-Free Autofluorescence Multi-Harmonic Microscopy
09:19

Simultaneous Label-Free Autofluorescence Multi-Harmonic Microscopy

Published on: August 29, 2025

587

Area of Science:

  • Neuroscience research within synchronous angular scanning microscopy
  • Biomedical engineering and optical physics

Background:

Deep tissue visualization remains a significant challenge for modern optical diagnostics due to light scattering within biological specimens. Traditional microscopy techniques often fail to penetrate beyond superficial layers in matured organisms. This gap motivated the development of methods capable of overcoming tissue turbidity. Prior research has shown that light-specimen interactions contain rich information about internal structures. However, extracting this data while correcting for sample-induced aberrations is technically demanding. No prior work had resolved the trade-off between imaging speed and the depth of non-invasive observation. That uncertainty drove the need for advanced interferometric recording systems. This study addresses these limitations by introducing a novel approach for high-speed, label-free imaging.

Purpose Of The Study:

The primary aim of this study is to develop a label-free imaging modality for deep, non-invasive observation of living biological systems. Researchers sought to overcome the limitations of existing techniques that are restricted by tissue turbidity. The project focuses on characterizing full light-specimen interactions to improve image resolution in deep tissue layers. This motivation stems from the need to study complex neural networks in their native states. The team aimed to replace conventional methods that often require physical dissection of matured specimens. They proposed a synchronous angular scanning microscope to achieve rapid, high-quality interferometric recording. The study addresses the challenge of removing high-order aberrations and multiple scattering noise during the imaging process. This work intends to expand the overall scope of applications for non-invasive optical interrogation in developmental biology.

Main Methods:

The review approach focuses on the implementation of a synchronous angular scanning microscope for interferometric data collection. Investigators designed this system to record the time-gated reflection matrix from biological samples. This setup characterizes the full interaction between light and the specimen during the scanning process. The team utilized a single scattering accumulation algorithm to process the acquired matrix data. This computational step effectively removes high-order sample-induced aberrations from the raw images. The protocol achieves an aberration correction speed of 10,000 modes per second. Researchers applied this methodology to observe the hindbrain of larval zebrafish at a matured developmental stage. This design allows for the visualization of neural networks without requiring physical dissection of the subject.

Main Results:

Key findings from the literature demonstrate that the synchronous angular scanning microscope successfully performs label-free imaging in vivo. The system achieves an effective aberration correction speed of 10,000 modes per second. By utilizing the single scattering accumulation algorithm, the researchers removed both high-order sample-induced aberrations and multiple scattering noise. This approach enabled the visualization of whole neural networks throughout the hindbrain of larval zebrafish. The imaging was conducted at a matured stage where conventional methods previously required physical dissection. The data indicate that the reflection matrix provides a unique characterization of full light-specimen interaction. These results confirm that the method overcomes limitations imposed by tissue turbidity in deeper biological layers. The technique provides a clear, non-invasive view of structures that were previously inaccessible to standard optical modalities.

Conclusions:

The authors propose that their synchronous angular scanning microscope provides a robust solution for deep-tissue, label-free observation. This synthesis suggests that the single scattering accumulation algorithm effectively mitigates noise from multiple scattering events. The findings imply that high-speed aberration correction is achievable at rates reaching 10,000 modes per second. The researchers claim that this method enables the visualization of neural networks in matured larval zebrafish. This approach removes the necessity for physical dissection during the examination of complex biological systems. The study indicates that non-invasive interrogation of living specimens is now more feasible than previously established. These results expand the potential scope for optical imaging in developmental biology. The authors conclude that their technique significantly enhances the clarity of images captured from deep within turbid biological environments.

The researchers propose that the system records a time-gated reflection matrix to characterize light-specimen interactions. By applying a single scattering accumulation algorithm, the device removes high-order aberrations and multiple scattering noise, achieving an effective correction speed of 10,000 modes per second.

The synchronous angular scanning microscope serves as the primary tool for rapid interferometric recording. Unlike traditional confocal systems, this apparatus captures the full reflection matrix, allowing for the mathematical separation of signal from background noise.

The authors state that time-gating is necessary to isolate the reflection matrix from scattered light. This temporal filtering ensures that only the relevant signals from the target depth are processed, which is essential for imaging through turbid tissue layers.

The reflection matrix acts as the primary data type, containing comprehensive information about the light-specimen interaction. This component allows the algorithm to distinguish between single scattering events and unwanted multiple scattering noise.

The researchers measured the system's performance by imaging the hindbrain of larval zebrafish. They observed that this method successfully visualized neural networks in matured specimens, a task that previously required physical dissection.

The authors claim that this method will expand the scope of applications for optical imaging. They suggest that fully non-invasive interrogation of living specimens is now possible, providing a new standard for studying biological systems in their native states.