Pediatric elbow measurement parameters: Evaluation of the six angles in inter- and intra-observer reliability
Purinon Suangyanon1, Ornusa Chalayon1, Kitti Worawuthangkul1
1Department of Orthopaedic Surgery, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand.
Background:
Several radiographic measurements of the humerus can be used to evaluate the treatment outcome of supracondylar fractures in children. Because of the cartilaginous nature of the immature elbow, interpretation of radiographs around this area is sometimes challenging and can be unreliable. This study was conducted to determine the inter-observer and intra-observer reliability of the six commonly used radiographic measurements of the distal humerus.
Method:
The Baumann angle, humero-ulna angle, metaphyseal-diaphyseal angle, radial epiphyseal angle, shaft-condylar angle and lateral capitellohumeral angle of the humerus were measured by two observers on the radiographs of uninjured elbows from 58 children. The values between each measurement were compared and correlated using a Pearson coefficient of correlation to determine the inter-observer and intra-observer reliability.
Results:
All of the radiographic parameters showed excellent intra-observer reliability with the correlation coefficient values of the Baumann angle, humero-ulna angle, metaphyseal-diaphyseal angle, radial epiphyseal angle, shaft-condylar angle, lateral capitellohumeral angle as 0.945, 0.95, 0.909, 0.888, 0.961 and 0.975 (p < 0.001), respectively. The inter-observer reliability of the Baumann and humero-ulna angles were also found to be highly correlated at r = 0.843 (p < 0.001) and 0.878 (p < 0.001), respectively. The metaphyseal-diaphyseal angle had poor reliability with r = 0.136 (p = 0.291) while the radial epiphyseal angle, shaft-condylar angle, and lateral capitellohumeral angle demonstrated good reliability with r = 0.675 (p < 0.001), 0.747 (p < 0.001), and 0.686 (p < 0.001), respectively.
Conclusion:
The Baumann angle and humero-ulna angle measurements of distal humerus showed excellent inter- and intra-observer reliability. Both parameters represent repeatable and reliable methods for determining the outcome of supracondylar humeral fractures in pediatric population.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
08:34Investigation into Deep Breathing through Measurement of Ventilatory Parameters and Observation of Breathing Patterns
Published on: September 16, 2019
Related Concept Videos
Naturalistic Observations
Reliability and Validity
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Wave Parameters
Angle of Twist: Problem Solving