Introduction of a Simple Algorithm to Create Synthetic-computed Tomography of the Head from Magnetic Resonance
Nahid Chegeni1, Mohamad Javad Tahmasebi Birgani2, Fariba Farhadi Birgani1
1Department of Medical Physics, Medical Physics, Faculty of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
Background:
Recently, magnetic resonance imaging (MRI)-based radiotherapy has become a favorite science field for treatment planning purposes. In this study, a simple algorithm was introduced to create synthetic computed tomography (sCT) of the head from MRI.
Methods:
A simple atlas-based method was proposed to create sCT images based on the paired T1/T2-weighted MRI and bone/brain window CT. Dataset included 10 patients with glioblastoma multiforme and 10 patients with other brain tumors. To generate a sCT image, first each MR from dataset was registered to the target-MR, the resulting transformation was applied to the corresponding CT to create the set of deformed CTs. Then, deformed-CTs were fused to generate a single sCT image. The sCT images were compared with the real CT images using geometric measures (mean absolute error [MAE] and dice similarity coefficient of bone [DSCbone]) and Hounsfield unit gamma-index (ГHU) with criteria 100 HU/2 mm.
Results:
The evaluations carried out by MAE, DSCbone, and ГHU showed a good agreement between the synthetic and real CT images. The results represented the range of 78-93 HU and 0.80-0.89 for MAE and DSCbone, respectively. The ГHU also showed that approximately 91%-93% of pixels fulfilled the criteria 100 HU/2 mm for brain tumors.
Conclusion:
This method showed that MR sequence (T1w or T2w) should be selected depending on the type of tumor. In addition, the brain window synthetic CTs are in better agreement with real CT relative to bone window sCT images.
More Related Videos
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies IV: Magnetic Resonance Imaging
Atomic Nuclei: Magnetic Resonance
Nuclear Magnetic Resonance (NMR): Overview
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...