Related Experiment Video
Updated: Jan 22, 2026

Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Feasibility of Single Channel Oximetry for Mass Screening of Obstructive Sleep Apnea
Joachim A Behar1, Niclas Palmius2, Qiao Li3
1Faculty of Biomedical Engineering, Technion, Israel Institute of Technology, Haifa, Israel.
Background:
The growing awareness for the high prevalence of obstructive sleep apnea (OSA) coupled with the dramatic proportion of undiagnosed individuals motivates the elaboration of a simple but accurate screening test. This study assesses, for the first time, the performance of oximetry combined with demographic information as a screening tool for identifying OSA in a representative (i.e. non-referred) population sample.
Methods:
A polysomnography (PSG) clinical database of 887 individuals from a representative population sample of São Paulo's city (Brazil) was used. Using features derived from the oxygen saturation signal during sleep periods and demographic information, a logistic regression model (termed OxyDOSA) was trained to distinguish between non-OSA and OSA individuals (mild, moderate, and severe). The OxyDOSA model performance was assessed against the PSG-based diagnosis of OSA (AASM 2017) and compared to the NoSAS and STOP-BANG questionnaires.
Findings:
The OxyDOSA model had mean AUROC = 0.94 ± 0.02, Se = 0.87 ± 0.04 and Sp = 0.85 ± 0.03. In particular, it did not miss any of the 75 severe OSA individuals. In comparison, the NoSAS questionnaire had AUROC = 0.83 ± 0.03, and missed 23/75 severe OSA individuals. The STOP-BANG had AUROC = 0.77 ± 0.04 and missed 14/75 severe OSA individuals.
Interpretation:
We provide strong evidence on a representative population sample that oximetry biomarkers combined with few demographic information, the OxyDOSA model, is an effective screening tool for OSA. Our results suggest that sleep questionnaires should be used with caution for OSA screening as they fail to identify many moderate and even some severe cases. The OxyDOSA model will need to be further validated on data recorded using overnight portable oximetry.
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Insufficient Sleep and Sleep Deprivation
Sleep deprivation is a more severe form of sleep loss...
Stages of Sleep
Before sleep begins, in wakefulness, the brain exhibits primarily beta waves, which are high in frequency and low in amplitude, indicating alertness...
Ion Channels
Ion channels are specialized integral membrane proteins on the plasma membrane that allow...
Understanding Sleep
The circadian rhythm, a nearly 24-hour cycle, is deeply influenced by environmental light cues. Light exposure directly affects the hypothalamus, which in turn regulates...

