Related Experiment Video
Updated: Jan 22, 2026

Quantification of the Immunosuppressant Tacrolimus on Dried Blood Spots Using LC-MS/MS
Published on: November 8, 2015
A Sensitive LC-MS/MS Assay for the Quantification of Methadone and its Metabolites in Dried Blood Spots: Comparison
Baharak Davari1, Nidhi Kotecha1, Claudia F Clavijo1
1Department of Anesthesiology, University of Colorado, Anschutz Medical Campus; and.
Introduction:
Methadone, a synthetic narcotic, is widely used both in adults and children for pain control and as a replacement drug in opioid use disorder to prevent craving and withdrawal. To support clinical pharmacokinetic trials in neonates, infants, and children, the authors developed and validated a novel, automated, highly sensitive liquid chromatography-electrospray-tandem mass spectrometry ionization (LC-ESI-MS/MS) method for the quantification of methadone and its metabolites, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) and 2-ethyl-5-methyl-3,3-diphenylpyraline (EMDP), in samples collected as dried blood spots.
Methods:
Blood was spiked with different concentrations of methadone, EDDP, and EMDP, and blood drops were applied to filter paper cards. Punches of 6.4 mm were removed from the cards, and 600 µL of protein precipitation solution (methanol/0.2M ZnSO4, 7:3, vol/vol) containing the internal standards (methadone-d9 and EDDP-d5) at a concentration of 1 mcg/L was added. The extracts were analyzed using LC-ESI-MS/MS in combination with online extraction. The mass spectrometer was run in the positive multiple reaction monitoring mode, and the total run time was 3.2 minutes.
Results:
For the dried blood spots, the assay has a lower limit of quantification of 0.1 mcg/L for methadone, EDDP, and EMDP. The range of reliable response for methadone for the ion transition m/z = 310.2→265.1 was 0.1-100 mcg/L and for the ion transition m/z = 310.2→223.1 5-1000 mcg/L. For EDDP, on the range of reliable response for the ion transition, m/z = 278.2→234.3 was 0.1-100 mcg/L and for the ion transition m/z = 278.2→186.1 5-1000 mcg/L. The calibration range for EMDP was 0.1-100 mcg/L. Accuracy (85%-115%) and imprecision (<15%) met predefined acceptance criteria.
Discussion:
This assay allows for the measurement of small volume blood samples without the need for an intravenous blood draw, and thus, it is suitable for pharmacokinetics studies and therapeutic drug monitoring in pediatric patients.
Related Concept Videos
Composition of Blood Plasma
Protein Buffers in Blood Plasma and Cells
Certain amino acids can exist in a zwitterion state at a...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Dry Friction
To illustrate this concept, imagine a wooden crate resting on a rough, non-uniform horizontal surface. When an external force is applied to...
Drying Shrinkage
A portion of this drying shrinkage can be reversed; if the concrete is...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...

